Randomized comparison of GR-II stent and Palmaz-Schatz stent for elective treatment of coronary stenoses.

نویسندگان

  • A J Lansky
  • G S Roubin
  • C D O'Shaughnessy
  • P B Moore
  • L S Dean
  • A E Raizner
  • R D Safian
  • J P Zidar
  • J L Kerr
  • J J Popma
  • R Mehran
  • R E Kuntz
  • M B Leon
چکیده

BACKGROUND This prospective multicenter randomized clinical trial was designed to evaluate the long-term angiographic and clinical outcomes of elective treatment with the GR-II stent compared with the Palmaz-Schatz (PS) stent in patients with coronary stenoses. METHODS AND RESULTS Seven hundred fifty-five patients with myocardial ischemia and de novo native coronary stenoses in 3- to 4-mm vessels were randomly assigned to the PS (375 patients) or the GR-II stent (380 patients). The primary end point was 12-month target lesion revascularization (TLR)-free survival. Angiography was performed at baseline and at follow-up in the first 300 consecutive patients to assess the frequency of angiographic restenosis. Procedure success was 98.5% for the GR-II stent and 99.4% for the PS stent (P:=0.19). At 30 days, patients assigned to the GR-II stent had a higher stent thrombosis rate (3.9% versus 0.3% for PS stent, P:<0.001) and TLR rate (3.9% versus 0.5% for PS stent, P:<0.001). The GR-II group had a higher follow-up restenosis frequency (47.3% versus 20.6% for the PS group, P:<0.001) and a lower 12-month TLR-free survival rate (71.7% versus 83.9% for the PS group, P:<0. 001). Multivariate logistic regression analysis identified a smaller final stent minimal lumen diameter (odds ratio [OR] 2.49, 95% CI 1. 56 to 3.98; P:<0.001), diabetes mellitus (OR 2.14, 95% CI 1.42 to 3. 22; P:<0.001), and use of the GR-II stent (OR 1.78, 95% CI 1.20 to 2. 64; P:<0.01) as independent determinants of 12-month TLR. CONCLUSIONS On the basis of these long-term follow-up data, we conclude that use of the GR-II stent should be limited to the acute treatment of abrupt or threatened closure after failed conventional balloon angioplasty procedures.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling and dose calculations of a pure beta emitting 32P coated stent for intracoronary brachytherapy by Monte Carlo code

Background: Recently, different investigators have studied the possibility of radiation therapy in restenosis prevention and have shown promising results. In this study a unique radioactive source for intra vascular brachytherapy (IVBT) was investigated. The two-dimensional dose distribution in water for a 32P IVBT stent has been calculated. The pure beta emitter source 32P has been co...

متن کامل

Comparison of Stent Designs using Computational Fluid Dynamics

Coronary artery disease (CAD) is one of the leading causes of death in the developed world. CAD occurs due to the build up of plaque in the coronary arteries which supply fresh blood to the constantly active heart muscle. Several methods exist to alleviate CAD such as coronary artery bypass grafting, balloon angioplasty and coronary stenting. A coronary stent is a small tubular prosthesis which...

متن کامل

Restenosis After Placement of Palmaz - Schatz Stents in Native Coronary Arteries

Background. Several metallic intracoronary stents are currently undergoing preliminary evaluation to ascertain potential benefit as means to reduce the 30-40% incidence of restenosis after balloon angioplasty. Methods and Results. To determine the incidence and correlates of restenosis after placement of Palmaz-Schatz stents in native coronary arteries in the first group of patients selected fo...

متن کامل

Facilitated advancement of the Palmaz-Schatz stent delivery system with the use of an adjacent 0.018" stiff wire.

The 5.0 French Palmaz-Schatz stent delivery system is a relatively bulky, stiff system which can be advanced only over a 0.014" wire. Although crossing failure is rare, advancement of the delivery system through tortuous, rigid vessels may be unsuccessful. We report on four consecutive cases in which the initial advancement of the Palmaz-Schatz stent delivery system was unsuccessful due to vess...

متن کامل

Determining prognosis early after a myocardial infarction.

[1] Serruys PW, de Jaegere P, Kiemeneij F et al. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group. N Engl J Med 1994; 331: 489–95. [2] Topol EJ, Leya F, Pinkerton CA et al. A comparison of directional atherectomy with coronary angioplasty in patients with coronary artery disease. The CAVEAT Study Group...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 102 12  شماره 

صفحات  -

تاریخ انتشار 2000