Preliminary Estimates of Performance and Cost of Mercury Emission Control Technology Applications on Electric Utility Boilers: An Update
نویسندگان
چکیده
The Environmental Protection Agency has recently proposed a reduction in mercury emissions from coal-fired power plants. There are two broad approaches under development to controlling mercury emissions from coal-fired electric utility boilers: (1) powdered activated carbon (PAC) injection, and (2) multipollutant control, in which Hg capture is enhanced in existing and new sulfur dioxide (SO2), nitrogen oxides (NOX), and particulate matter (PM) control devices. To help inform the recent EPA rulemaking proposal, estimates of performance levels and related costs associated with the above mercury control approaches were developed. This work presents these estimates. Estimates of cost for PAC injection range from 0.03-3.096 mills/kWh. In general, the higher costs are associated with the plants using spray dryers and electrostatic precipitators (ESPs) or plants using hot-side ESPs, which represent a minority of power plants. Excluding these plants, cost estimates range between 0.03 and 1.903 mills/kWh. At the low end of the cost ranges, 0.03 mills/kWh, it is assumed that no additional control technologies are needed, but mercury monitoring will be necessary. In these cases, high mercury removal may be the result of the type of NOx and SO2 control measures currently employed, such as combinations of selective catalytic reduction and wet flue gas desulfurization on bituminous coal fired boilers. Since mercury control approaches are under development at present, cost and performance estimates are preliminary and are expected to be refined as mercury control technologies are matured to commercial status. Factors that may affect the performance of these technologies include speciation of mercury in flue gas, the characteristics of the sorbent, and the type(s) of PM, NOx and SO2 controls employed. The effect of these factors may not be entirely accounted for in the data points that form the basis for this work. Ongoing research is expected to address these issues.
منابع مشابه
Mercury Emissions Control from Existing Utility and Industrial Boilers
Industrial, commercial, and institutional (ICI) boilers are one of the major sources of hazardous air pollutants (HAP), including mercury (Hg). Coal-fired electric power plants constitute the largest point source of anthropogenic Hg in the United States. The primary objective of this paper was to address the mercury side of the boiler maximum achievable control technology (MACT) of the national...
متن کاملControl of mercury emissions from coal-fired electric utility boilers.
Introduction During combustion, the mercury (Hg) in coal is volatilized and converted to elemental mercury (Hg) vapor in the high temperature regions of coal-fired boilers. As the flue gas is cooled, a series of complex reactions begin to convert Hg to ionic mercury (Hg) compounds and/or Hg compounds (Hgp) that are in a solid-phase at flue gas cleaning temperatures or Hg that is adsorbed onto t...
متن کاملMercury Control Alternatives for Coal-fired Power Plants
Coal-fired power plants in the United States may have to reduce their mercury emissions by up to 90% by 2007 2009 due to proposed regulations that could affect up to 1,100 utility boilers. Air pollution control system components such as electrostatic precipitators, baghouses, NOx reduction catalysts, SO2 scrubbers, and their various configurations in utility applications significantly impact me...