Calculation of Positron Response from Embedded Nanoparticles

نویسنده

  • J. Kuriplach
چکیده

Nanoparticles embedded in a matrix can trap positrons under certain conditions. In such cases nanoparticles can be effectively studied by means of positron annihilation because positron annihilation characteristics contain information related to nanoparticles’ electronic and atomic structure. Of great importance is to calculate the positron response from such nanoparticles. Then, nanoparticles can, in principle, be identified by comparing the measured and calculated positron annihilation response. For this purpose we present an efficient computational method based on the well-known atomic superposition technique. This method is explained in detail, justified on the basis of first principles calculations, and applied to Cu nanoparticles embedded in the Fe matrix.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit

Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...

متن کامل

Positron annihilation lifetime spectroscopy in nickel ferrite and iron oxide nanopowders

In this study, a positron annihilation lifetime spectrometer was set up and its resolution was optimized. The spectrometer is a fast-slow arrangement with time resolution of 250 ps. To obtain lifetime components and their intensities from analyzing positron annihilation lifetime spectrum, the Pascual software is used. Positrons are from a source of radioactive 22NaCl with 20 μCi activity enclos...

متن کامل

The microscopic dose enhancement factor measurment of bismuth nanoparticles in external radiation therapy using MRI polymer gel dosimetery

Introduction: Bismuth-based nanoparticles having high atomic number and electron density, besides of being utilized as CT contrast agent, stand as a strongly proposed method for dose enhancement in radiotherapy. Embedded nanoparticle in polymer gel dosimeter poses the first step to assess the dose enhancement capability in nanoparticles. To this end, MAGICA gel dosimeter, whic...

متن کامل

Embedding Ultrafine and High‐Content Pt Nanoparticles at Ceria Surface for Enhanced Thermal Stability

Ultrafine Pt nanoparticles loaded on ceria (CeO2) are promising nanostructured catalysts for many important reactions. However, such catalysts often suffer from thermal instability due to coarsening of Pt nanoparticles at elevated temperatures, especially for those with high Pt loading, which leads to severe deterioration of catalytic performances. Here, a facile strategy is developed to improv...

متن کامل

Effect of scatter coincidences, partial volume, positron range and non-colinearity on the quantification of FDOPA Patlak analysis

Introduction: The key characteristics of positron emission tomography (PET) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. Therefore, accurate quantification is important. However, it can be sensitive to several physical factors. The aim of this investigation is the assessment of the e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005