In vitro Dosimetric Study of Biliary Stent Loaded with Radioactive 125I Seeds
نویسندگان
چکیده
BACKGROUND A novel radioactive 125I seed-loaded biliary stent has been used for patients with malignant biliary obstruction. However, the dosimetric characteristics of the stents remain unclear. Therefore, we aimed to describe the dosimetry of the stents of different lengths - with different number as well as activities of 125I seeds. METHODS The radiation dosimetry of three representative radioactive stent models was evaluated using a treatment planning system (TPS), thermoluminescent dosimeter (TLD) measurements, and Monte Carlo (MC) simulations. In the process of TPS calculation and TLD measurement, two different water-equivalent phantoms were designed to obtain cumulative radial dose distribution. Calibration procedures using TLD in the designed phantom were also conducted. MC simulations were performed using the Monte Carlo N-Particle eXtended version 2.5 general purpose code to calculate the radioactive stent's three-dimensional dose rate distribution in liquid water. Analysis of covariance was used to examine the factors influencing radial dose distribution of the radioactive stent. RESULTS The maximum reduction in cumulative radial dose was 26% when the seed activity changed from 0.5 mCi to 0.4 mCi for the same length of radioactive stents. The TLD's dose response in the range of 0-10 mGy irradiation by 137Cs γ-ray was linear: y = 182225x - 6651.9 (R2=0.99152; y is the irradiation dose in mGy, x is the TLDs' reading in nC). When TLDs were irradiated by different energy radiation sources to a dose of 1 mGy, reading of TLDs was different. Doses at a distance of 0.1 cm from the three stents' surface simulated by MC were 79, 93, and 97 Gy. CONCLUSIONS TPS calculation, TLD measurement, and MC simulation were performed and were found to be in good agreement. Although the whole experiment was conducted in water-equivalent phantom, data in our evaluation may provide a theoretical basis for dosimetry for the clinical application.
منابع مشابه
Dosimetric comparison between four kinds of radioactive esophageal stents to be used in the treatment of advanced esophageal cancers using Monte Carlo simulation
Finding accurate methods to be employed for the treatment of esophageal cancers is of especial interest for researchers, due to the sensitivity of this tissue. Recently radioactive stents loaded with I-125 brachytherapy seeds have been widely investigated for the treatment of advanced esophageal cancer. It is necessary to investigate the dose distribution of any radioactive esophageal stents be...
متن کاملStenting of the Portal Vein Combined with Different Numbers of Iodine-125 Seed Strands: Dosimetric Analyses
Background: Portal-vein stent combined with one iodine-125 (125I) seed strand has become a new treatment for portal vein tumor thrombosis. However, dosimetric aspects of this irradiation stent have not been reported. Therefore, we aimed to undertake dosimetric analyses comparing portal-vein stents combined with different numbers of 125I seed strands. Methods: A water cylinder was created by a...
متن کاملPreventive effects of 125I seeds on benign restenosis following esophageal stent implantation in a dog model
The present study aimed to evaluate the effects of iodine‑125 (125I) seeds on the proliferation of primary esophageal fibroblasts in dogs, and to assess the safety and preventive efficacy of 125I seed‑pre‑loaded esophageal stents in benign restenosis following implantation. Primary fibroblasts were cultured with various 125I seed activities, which were then evaluated using cell proliferation an...
متن کاملComparative study of self-expanding metal stent and intraluminal radioactive stent for inoperable esophageal squamous cell carcinoma
BACKGROUND We compared the effectiveness of self-expanding metal stent alone vs. radioactive stent embedded with 125I seeds implantation insertion in patients of inoperable esophageal squamous cell cancer combined with malignant esophageal stenosis. METHODS We studied two groups of patients with stenosis attribute to inoperable esophageal squamous cell carcinoma. Group A had placed self-expan...
متن کاملRadioactive self-expanding stents give superior palliation in patients with unresectable cancer of the esophagus but should be used with caution if they have had prior radiotherapy.
BACKGROUND Self-expandable stents loaded with 125I (iodine 125) seeds may combine the advantages of the immediate relief of esophageal dysphagia with stent placement and radiation therapy with brachytherapy. We compared the self-expanding irradiation stent with a conventional self-expandable covered stent in patients with malignant dysphagia due to recurrent esophageal cancer. METHODS The pat...
متن کامل