A new contact lens for posterior vitreous photodisruption.

نویسندگان

  • P Rol
  • F Fankhauser
  • S Kwasniewska
چکیده

Effective and safe photodisruption requires that the laser pulse be brought to a fine focus. Contact lenses are generally required to compensate for the optical aberrations of the eye which degrade the laser focus. The theoretical analysis of these aberrations has led to the construction of a contact lens which minimizes aberrations in the posterior vitreous. Clinical applications confirm the increased efficacy and safety of posterior vitreous photodisruption using this contact lens.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Analysis of the Thermal Interaction of Cell Phone Radiation with Human Eye Tissues

Introduction: The present study aimed to present a numerical analysis of the penetration depth,  specific absorption rate (SAR), and temperature rise in various eye tissues with varying distance between radiation source and exposed human eye tissues (i.e., cornea, posterior chamber, anterior chamber, lens, sclera, vitreous humor, and iris) at frequencies of 900 and1800 MHz. Materials and Method...

متن کامل

[Peripheral vitreoretinal traction exploration by Staurenghi 230 lens and HRA-II].

PURPOSE To report a new technique to explore peripheral vitreous-retinal tractions in patients with acute posterior vitreous detachment. MATERIAL AND METHODS A population of 65 patients with acute posterior vitreous detachment was studied by panfunduscopic SLO 230 lens and HRA-II to detect peripheral retinal tears and vitreous-retinal tractions. RESULTS In our study, using indirect ophthalm...

متن کامل

Combined use of high-reflective index vitrectomy meniscus contact lens and a noncontact wide-angle viewing system in vitreous surgery

BACKGROUND The aim of this study was to assess the combined use of a high-reflective index vitrectomy (HHV) meniscus contact lens and a noncontact wide-angle viewing system in vitreous surgery. METHODS Twenty-three gauge vitrectomy was performed with combined use of a HHV meniscus contact lens and a noncontact wide-angle viewing system. When delicate manipulation of the retina such as interna...

متن کامل

Ultrasound biomicroscopic analysis of pseudophakic pupillary block glaucoma induced by Soemmering's ring.

AIM To perform ultrasound biomicroscopic analysis of pseudophakic pupillary block glaucoma induced by lens capsule and a Soemmering's ring and its resolution, and to elucidate the pathophysiology of this glaucoma. METHODS A woman with pseudophakic pupillary block glaucoma underwent successful neodymium:YAG (Nd:YAG) laser photodisruption of the lens capsule through a laser iridotomised colobom...

متن کامل

بررسی تأثیر اعمال جراحی پیوند ثانویه عدسی داخل چشمی

Background and purpose : Many aphahic patients have unfavorable vision either with glasses or contact lens. In this study Visual outcome of Seconary (I.O.L) was implantation in aphakic patients referred to Imam Hossein Haspital 1994 evaluated. Materials and Methods : In a clinical trial with sequential sampling , 30 aphakic patients (26 males , 4 females mean of age 24.4 ± 10.8 years) who...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 27 6  شماره 

صفحات  -

تاریخ انتشار 1986