Development of a High Volume Cascade Impactor for Toxicological and Chemical Characterization Studies

نویسندگان

  • P. Demokritou
  • P. Koutrakis
چکیده

This paper presents the design and development of a compact high volume cascade impactor (HVCI). The HVCI operates at a  ow rate of 900 l/min and consists of 4 impaction stages equipped with circular slit-shaped acceleration nozzles and a backup Ž lter. The backup Ž lter is placed downstream of the fourth stage and is used to collect the ultraŽ ne particles (dp < 0.1 1m). The major feature of this novel sampler is its ability to collect relatively large amounts of particles (mg–g levels) onto relatively small polyurethane foam substrates without using adhesives. As previously reported, the capacity of the impaction substrate is 2.15 g of collected particles per cm of foam. Although the impaction substrates are not coated with adhesives such as grease or mineral oil, particle bounce and re-entrainment losses were found not to be signiŽ cant. Particles can be easily recovered from the foam substrates using aqueous extraction. The impactor was calibrated using polydisperse particles. The 50% cutpoints of the 4 stages were 9.90, 2.46, 1.0, and 0.1 1m, respectively. Interstage losses of ultraŽ ne and Ž ne particles were <10% and for coarse particleswere<20%. The pressure drop across the 4 stages and the backup Ž lter were 0.25, 0.75, 1.25, 19.9, and 3.3 kPa, respectively.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Title of Thesis : FLUID AND PARTICLE DYNAMICS IN AN AEROSOL VIRTUAL IMPACTOR

Title of Thesis: FLUID AND PARTICLE DYNAMICS IN AN AEROSOL VIRTUAL IMPACTOR Marwan L. Charrouf, Master of Science, 2004 Thesis Directed by: Professor Richard V. Calabrese Department of Chemical Engineering The collection and characterization of chemical and biological aerosols is essential to many areas of particle research such as toxicological studies, pollutant sampling, and biohazard assess...

متن کامل

Numerical Investigation on Compressible Flow Characteristics in Axial Compressors Using a Multi Block Finite Volume Scheme

An unsteady two-dimensional numerical investigation was performed on the viscous flow passing through a multi-blade cascade. A Cartesian finite-volume approach was employed and it was linked to Van-Leer's and Roe's flux splitting schemes to evaluate inviscid flux terms. To prevent the oscillatory behavior of numerical results and to increase the accuracy, Monotonic Upstream Scheme for Conservat...

متن کامل

Preparation, Statistical Optimization and In-vitro Characterization of a Dry Powder Inhaler (DPI) Containing Solid Lipid Nanoparticles Encapsulating Amphotericin B: Ion Paired Complexes with Distearoyl Phosphatidylglycerol

The aim of this study was to prepare dry powder inhalers (DPIs) containing amphotericin B-loaded solid lipid nanoparticles (AMB-SLNs) as an alternative approach for prevention of pulmonary aspergillosis. For solubilizing AMB in small amounts of organic solvents ion paired complexes were firstly formed by establishing electrostatic interaction between AMB and distearoyl phosphatidylglycerol (DSP...

متن کامل

Environmental Control Systems for Defining the Activity Size Distribution of Radioactive Aerosols - a Case Study

The 1ACFM cascade impactor and the High Volume cascade impactors are the instruments that mainly used to define the activity size distribution of radioactive aerosols in the environmental air. The impactors are instruments designed to collect and separate particulate matter according to its aerodynamic size, determining the penetration of particles in the human lung, as well as the transport an...

متن کامل

Preparation, Statistical Optimization and In-vitro Characterization of a Dry Powder Inhaler (DPI) Containing Solid Lipid Nanoparticles Encapsulating Amphotericin B: Ion Paired Complexes with Distearoyl Phosphatidylglycerol

The aim of this study was to prepare dry powder inhalers (DPIs) containing amphotericin B-loaded solid lipid nanoparticles (AMB-SLNs) as an alternative approach for prevention of pulmonary aspergillosis. For solubilizing AMB in small amounts of organic solvents ion paired complexes were firstly formed by establishing electrostatic interaction between AMB and distearoyl phosphatidylglycerol (DSP...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003