Hyperpolarized [1-C]-Lactate as a Tool for the In Vivo Investigation of Cardiac Metabolism
نویسندگان
چکیده
slice through the heart acquired with dynamic spCSI after injection of hyperpolarized [1-C]-lactate. The images were averaged over 4 time points (10 to 25 s). Fig. 1: (a) Time courses of Lac, Pyr, and Bic from a 15-mm slice through a rat heart in vivo after injection of 2.8 mL hyperpolarized [1-C]pyruvate (BGL = 137mg/dL). (b) Same as (a), but after injection of 2.8 mL hyperpolarized [1-C]-lactate (BGL = 146 mg/dL). Hyperpolarized [1-C]-Lactate as a Tool for the In Vivo Investigation of Cardiac Metabolism
منابع مشابه
Reproducibility study for free-breathing measurements of pyruvate metabolism using hyperpolarized (13) C in the heart.
Spatially resolved images of hyperpolarized (13) C substrates and their downstream products provide insight into real-time metabolic processes occurring in vivo. Recently, hyperpolarized (13) C pyruvate has been used to characterize in vivo cardiac metabolism in the rat and pig, but accurate and reproducible measurements remain challenging due to the limited period available for imaging as well...
متن کاملAssessment of Metformin induced changes in cardiac redox state using hyperpolarized[1-13C]pyruvate
Background Metformin improves cardiovascular outcomes in diabetes, but its mechanism of action is controversial. Recent evidence suggests that Metformin reduces gluconeogenesis by altering hepatic redox state. Whether Metformin also alters cardiac redox state and metabolism is unknown, in part because of the difficulty in measuring cardiac metabolism in vivo. Hyperpolarized [1-C]pyruvate magnet...
متن کاملMetabolism of Hyperpolarized 1-C-Lactate in Living Breast Cancer Cell Cultures
Introduction The recent development of a technique to enhance C NMR polarizations by ≥10,000x may allow us to follow metabolic processes non-invasively with unprecedented sensitivity and temporal resolution [1]. The importance of such development for in vivo metabolic imaging is clear and many important works have been done showing the utility of hyperpolarized metabolic imaging both in cancer ...
متن کاملIn Vivo Monitoring of Rat Spinal Cord Metabolism Using Hyperpolarized Carbon-13 MR Spectroscopic Imaging.
This study demonstrated the feasibility of using hyperpolarized 13C-MR spectroscopic imaging with [1-13C]-pyruvate to evaluate in vivo spinal cord metabolism. High pyruvate and relatively small lactate signal were observed in the cervical spinal cords of naive rats. Lactate and pyruvate measures were similar for spinal cord and supratentorial brain. The results from this study establish baselin...
متن کاملDynamic 1H imaging of hyperpolarized [1‐13C]lactate in vivo using a reverse INEPT experiment
PURPOSE Dynamic magnetic resonance spectroscopic imaging of hyperpolarized 13 C-labeled cell substrates has enabled the investigation of tissue metabolism in vivo. Currently observation of these hyperpolarized substrates is limited mainly to 13 C detection. We describe here an imaging pulse sequence that enables proton observation by using polarization transfer from the hyperpolarized 13 C nucl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -