The bovine corneal opacity and permeability test in routine ocular irritation testing and its improvement within the limits of OECD test guideline 437.
نویسندگان
چکیده
Data on eye irritation are generally needed for the hazard identification of chemicals. As the Bovine Corneal Opacity and Permeability (BCOP) test has been accepted by many regulatory agencies for the identification of corrosive and severe ocular irritants since September 2009 (OECD Test Guideline 437, TG 437), we evaluated this alternative method for routine testing at BASF. We demonstrated our technical proficiency by testing the reference standards recommended in TG 437, and 21 additional materials with published BCOP and in vivo data. Our results matched the published in vitro data very well, but with some intentionally selected false negatives (FNs) and false positives (FPs), the concordance was 77% (24/31), with FN and FP rates of 20% (2/10) and 24% (5/21), respectively. In addition, we tested 21 in-house materials, demonstrating the utility of the BCOP assay for our own test material panel. Histopathological assessment of the corneas by light microscopy was also conducted, as this was suggested as a means of improving the identification of FNs. The histopathology corrected the classification of some FNs, but also increased the number of FPs. Parallel to the test method evaluation, we compared three new opacitometer models with the current standard device. We recommend the use of an opacitometer developed in our BASF laboratory, which has certified components and electronic data storage, resulting in what we consider to be excellent sensitivity, stability and reproducibility.
منابع مشابه
Histopathological evaluation of the ocular-irritation potential of shampoos, make-up removers and cleansing foams in the bovine corneal opacity and permeability assay
The bovine corneal opacity and permeability (BCOP) assay is an alternative method to the in vivo Draize eye test in rabbits for evaluating eye irritation in vitro. Here, we compared the numerical results of the BCOP assay with the corresponding histopathology for three different corneas for each test substance, including commercially available shampoos, make-up removers and cleansing foams that...
متن کاملTiO2 Nanoparticles as a Common Component of Sunscreens: An Experimental Study of Dermal/Ocular Safety Assessment
Background: The safety evaluations of sunscreens containing Titanium Dioxide-Nanoparticles (TiO2-NPs) were done by dermal exposure, acute dermal and eye irritation/corrosion, and skin sensitization according to the guideline for Organization for Economic Co-operation and Development (OECD). OBJECTIVES: The aim of our study was the evaluation of safety and toxicity of TiO2-NPs following acute su...
متن کاملEXPERT PANEL REPORT: Evaluation of the Current Validation Status of In Vitro Test Methods for Identifying Ocular Corrosives and Severe Irritants (March 2005) III. Bovine Corneal Opacity and Permeability Test Method
Page 57 § 1.1.2.: it is mentioned that some materials can cause serious corneal injury without appearing to change opacity or permeability immediately (e.g. mustard gas). Is this a specific observation for mustard gas or are other examples (agents) known which can induce damage without changes in opacity and/or permeability? Injury (cell death) without any change in opacity and/or permeability ...
متن کاملThe Bovine Cornea Opacity and Permeability Test
An in vitro test for the development of corneal opacity in response ocular irritants was first proposed by Muir (1984). This test required the clamping of a bovine cornea between two chambers filled with physiologic saline and measuring the transmittance of white light through the cornea using the voltage output of a photocell. This was followed by exposure of the epithelial surface of the corn...
متن کاملSafety assessment of a novel active ingredient, acetyl aspartic acid, according to the EU Cosmetics Regulation and the Scientific Committee on Consumer Safety guidelines.
OBJECTIVE Acetyl aspartic acid (A-A-A) was proposed as a new novel active ingredient for use in cosmetics. The safety of A-A-A was assessed by following an in-house-developed 'New Ingredient Testing Strategy', which was designed in accordance with the Scientific Committee on Consumer Safety (SCCS) notes of guidance and the requirements of Annex I of the EU Cosmetics Regulation. The aim of the p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Alternatives to laboratory animals : ATLA