The teller acuity cards are effective in detecting amblyopia.
نویسندگان
چکیده
PURPOSE Detection of amblyopia in infants and toddlers is difficult because the current clinical standard for this age group, fixation preference, is inaccurate. Although grating acuity represents an alternative, studies of preschoolers and schoolchildren report that it is not equivalent to the gold standard optotype acuity. Here, we examine whether the Teller Acuity Cards (TAC) can detect amblyopia effectively by testing children old enough (7.8 +/- 3.6 years) to complete optotype acuity testing. METHODS Grating acuity was assessed monocularly in 45 patients with unilateral amblyopia, 44 patients at risk for amblyopia, and 37 children with no known vision disorders. Each child's grating acuity was classified as normal/abnormal based on age-appropriate norms. These classifications were compared with formal amblyopia diagnoses. RESULTS Grating acuity was finer than optotype acuity among amblyopic eyes (medians: 0.28 vs. 0.40 logMAR, respectively, p < 0.0001) but not among fellow eyes (medians: 0.03 vs. 0.10 logMAR, respectively, p = 0.36). The optotype acuity-grating acuity discrepancy among amblyopic eyes was larger for cases of severe amblyopia than for moderate amblyopia (means: 0.64 vs. 0.18 logMAR, respectively, p = 0.0001). Nevertheless, most cases of amblyopia were detected successfully by the TAC, yielding a sensitivity of 80%. Furthermore, grating acuity was relatively sensitive to all amblyopia subtypes (69 to 89%) and levels of severity (79 to 83%). CONCLUSIONS Although grating acuity is finer than optotype acuity in amblyopic eyes, most children with amblyopia were identified correctly suggesting that grating acuity is an effective clinical alternative for detecting amblyopia.
منابع مشابه
Comparative efficacy of penalization methods in moderate to mild amblyopia.
PURPOSE To compare the efficacy and sensory outcome of pharmacologic and optical penalization in the treatment of moderate to mild amblyopia. DESIGN Randomized clinical trial. METHODS In an institutional setting, two- to 10-year-old children with strabismic or anisometropic amblyopia (visual acuity in the amblyopic eye at least 20/60) who were cooperative to measure visual acuity using the ...
متن کاملScreening for amblyopia: a comparison of paediatric letter tests.
AIMS/BACKGROUND The measurement of visual acuity is the most widely accepted indicator of amblyopia and is thought by some to be the only effective screening test. The aim of this study was to investigate the effectiveness of the traditional single optotype Sheridan-Gardiner test (SGT) in the measurement of visual acuity and the detection of amblyopia, compared with the log based linear format ...
متن کاملTraining the adult amblyopic eye with "perceptual learning" after vision loss in the non-amblyopic eye.
We recently reported acuity development in the amblyopic eye of a 60-year-old patient after loss of vision in her non-amblyopic eye. Here, we focus on the training that we implemented, based on new insights from psychophysical procedures aiming at functional visual improvement of adults ("perceptual learning"). We alternately used the following procedures: grating acuity (Teller-Cards); contras...
متن کاملGrating visual acuity using the preferential-looking method in elderly nursing home residents.
PURPOSE To assess the performance of two approaches to visual acuity testing in a group of nursing home residents with cognitive impairment. The study was a cross-sectional comparison of the effectiveness of two tests of visual acuity. METHODS Nursing home residents participating in a clinical trial were tested with both recognition acuity charts and grating acuity cards (Teller) by masked ob...
متن کاملAstigmatism and acuity in two primate infants.
The development of grating acuity was followed in two astigmatic primate infants, one a human being and one a pigtail macaque monkey. Both infants showed variations of acuity with grating orientation, predictable from the orientation and type of astigmatism present. Optical correction of the human infant during testing virtually eliminated the variation of acuity with orientation, suggesting th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optometry and vision science : official publication of the American Academy of Optometry
دوره 86 6 شماره
صفحات -
تاریخ انتشار 2009