PFC / JA - 93 - 16 Electron Distribution Function Measurements on a Magnetron Injection Gun Beam
نویسندگان
چکیده
The parallel electron distribution function has been measured on an electron beam from a magnetron injection gun (MIG) using an E 11 B energy analyzer. The magnetic field, beam voltage and beam current were scaled down from normal operating parameters. The perpendicular velocity spread, inferred under the assumption that the electrons are mono-energetic, is relatively constant for electron velocity ratios #//011 > 0.7 and increases approximately linearly with the beam current. The current scaling of the perpendicular velocity spread is also consistent with electron loss currents measured at the control anode of the MIG. Observed perpendicular velocity spreads for the gun design parameters are substantially larger than computational values.
منابع مشابه
Preprint PFC/JA-83-7 RADIATION MEASUREMENTS FROM AN INVERTED RELATIVISTIC MAGNETRON
We report microwave emission measurements from an inverted relativistic magnetron comprising an outer cylindrical field emission cathode and an inner coaxial anode with embedded vane resonators. The magnetron operates in the w mode at a frequency of %3.6GHz, and voltages of 1-2MV. The RF power is %500MW.
متن کاملFormation of Laminar Electron Flow for a High-Power Sub-THz Gyrotron
This paper describes the design of a magnetron-injection gun for a 100 kW, 300 GHz gyrotron. With an increase in power and frequency, performance of the gyrotron becomes quite sensitive to the quality of the electron beam. Formation of a laminar electron flow is essential for the realization of a high quality beam with small velocity spread. In this study, a new method is proposed for the evalu...
متن کاملUniformity for a Magnetron Injection Gun
We report measurements of the azimuthal emission nonuniformity of a gyrotron's thermionic cathode as determined from two experiments, one which determines the total emission and one which scans the emitted beam using a rotating probe. In the total emission experiment, which measured the total collector current over a range of voltages, the cathode's total work function spread was found to be 0....
متن کاملSingle-pass High-gain Free Electron Laser Electron Beam Diagnostics
Consensus reached in the last few years that fourth generation light source will most likely be a X-ray or a UV coherent source based on single-pass high-gain free electron laser (FEL), such as Self Amplified Spontaneous Emission (SASE), or seeded high-gain harmonic -generation (HGHG) free electron lasers. High -gain (> 10) required for single-pass FEL puts great constrain on the quality of ele...
متن کاملPFC / JA - 82 - 33 Cross - field Free Electron Laser Instability for a Tenuous Electron Beam
The free electron laser instability is investigated for a tenuous circulating electron beam propagating perpendicular to a uniform magnetic field B 0 , and transverse wiggler field modeled by B. sin ky, in planar geometry. Unlike the rippled-field magnetron which operates at Brillouin flow, the present analysis assumes a low-density electron beam with w. 4D '. Making use of a macroscopic cold-f...
متن کامل