Validity of sports watches when estimating energy expenditure during running

نویسندگان

  • Lilian Roos
  • Wolfgang Taube
  • Nadja Beeler
  • Thomas Wyss
چکیده

Background The aim of this study was to assess the accuracy of three different sport watches in estimating energy expenditure during aerobic and anaerobic running. Methods Twenty trained subjects ran at different intensities while wearing three commercial sport watches (Suunto Ambit2, Garmin Forerunner920XT, and Polar V800). Indirect calorimetry was used as the criterion measure for assessing energy expenditure. Different formulas were applied to compute energy expenditure from the gas exchange values for aerobic and anaerobic running. Results The accuracy of the energy expenditure estimations was intensity-dependent for all tested watches. During aerobic running (4-11 km/h), mean absolute percentage error values of -25.16% to +38.09% were observed, with the Polar V800 performing most accurately (stage 1: -12.20%, stage 2: -3.61%, and stage 3: -4.29%). The Garmin Forerunner920XT significantly underestimated energy expenditure during the slowest stage (stage 1: -25.16%), whereas, the Suunto Ambit2 significantly overestimated energy expenditure during the two slowest stages (stage 1: 38.09%, stage 2: 36.29%). During anaerobic running (14-17 km/h), all three watches significantly underestimated energy expenditure by -21.62% to -49.30%. Therefore, the error in estimating energy expenditure systematically increased as the anaerobic running speed increased. Conclusions To estimate energy expenditure during aerobic running, the Polar V800 is recommended. By contrast, the other two watches either significantly overestimated or underestimated energy expenditure during most running intensities. The energy expenditure estimations generated during anaerobic exercises revealed large measurement errors in all tested sport watches. Therefore, the algorithms for estimating energy expenditure during intense activities must be improved before they can be used to monitor energy expenditure during high-intensity physical activities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimating Heart Rate, Energy Expenditure, and Physical Performance With a Wrist Photoplethysmographic Device During Running

BACKGROUND Wearable sensors enable long-term monitoring of health and wellbeing indicators. An objective evaluation of sensors' accuracy is important, especially for their use in health care. OBJECTIVE The aim of this study was to use a wrist-worn optical heart rate (OHR) device to estimate heart rate (HR), energy expenditure (EE), and maximal oxygen intake capacity (VO2Max) during running an...

متن کامل

Global positioning system watches for estimating energy expenditure.

Global positioning system (GPS) watches have been introduced commercially, converting frequent measurements of time, location, speed (pace), and elevation into energy expenditure (EE) estimates. The purpose of this study was to compare EE estimates of 4 different GPS watches (Forerunner, Suunto, Polar, Adeo), at various walking speeds, with EE estimate from a triaxial accelerometer (RT3), which...

متن کامل

Validity and reliability of Nike + Fuelband for estimating physical activity energy expenditure.

BACKGROUND The Nike + Fuelband is a commercially available, wrist-worn accelerometer used to track physical activity energy expenditure (PAEE) during exercise. However, validation studies assessing the accuracy of this device for estimating PAEE are lacking. Therefore, this study examined the validity and reliability of the Nike + Fuelband for estimating PAEE during physical activity in young a...

متن کامل

Energy expenditure estimates of the Caltrac accelerometer for running, race walking, and stepping.

OBJECTIVE To examine the accuracy of the Caltrac accelerometer for estimating energy expenditure (EE) during three exercise modes. METHODS A subset of 31 women (mean (SEM) age 22.6 (5) years) as selected from a training study comparing various physiological parameters during race walking, running, and stepping. Subjects each performed mode specific graded exercise tests to peak VO2. Regressio...

متن کامل

High Resolution MEMS Accelerometers to Estimate VO2 and Compare Running Mechanics between Highly Trained Inter-Collegiate and Untrained Runners

BACKGROUND The purposes of this study were to determine the validity and reliability of high resolution accelerometers (HRA) relative to VO(2) and speed, and compare putative differences in HRA signal between trained (T) and untrained (UT) runners during treadmill locomotion. METHODOLOGY Runners performed 2 incremental VO(2max) trials while wearing HRA. RMS of high frequency signal from three...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017