An animal paired crossover ePTFE arteriovenous graft model
نویسندگان
چکیده
PURPOSE Previously, we developed a porcine model for Arterio Venous Graft (AVG) failure to allow assessment of new access strategies. This model was limited concerning graft length. In the present technical report, we describe a modification of our model allowing the assessment of long AVGs. TECHNIQUE In 4 pigs, AVGs of 15 cm length were created bilaterally in a cross-over fashion between the carotid artery and the contralateral jugular vein. Two days (2 pigs) and two weeks (2 pigs) after AV shunting, graft patency was evaluated by angiography, showing all four grafts to be patent, with no sign of angiographic or macroscopic narrowing at the anastomoses sites. CONCLUSIONS In this modified pig AVG failure model, implantation of a bilateral cross-over long AVG is a feasible approach. The present model offers a suitable tool to study local interventions or compare various long graft designs aimed at improvement of AVG patency.
منابع مشابه
Infectious complications of arteriovenous ePTFE grafts for hemodialysis.
BACKGROUND Insufficient venous vasculature disallows autologous arteriovenous fistula creation. In this case an arteriovenous conduit of expanded polytetrafluoroethylene (ePTFE) interponed between artery and vein is used for hemodialysis. Although arteriovenous graft infection is an infrequent complication, infected grafts cannot be used for hemodialysis and can cause infection, sepsis and blee...
متن کاملCost efficacy of duplex surveillance and prophylactic angioplasty of arteriovenous ePTFE grafts.
Poor patency of arteriovenous ePTFE grafts remains a major clinical problem. Prophylactic balloon angioplasty of stenoses has been claimed to prolong graft patency and has been widely introduced into practice. In this manuscript we report the cost incurred in application of such a program involving graft surveillance and prophylactic angioplasty of ePTFE graft stenoses >50% diameter. All patien...
متن کاملTiming of cannulation of arteriovenous grafts: are we too cautious?
BACKGROUND Timing of first cannulation of an arteriovenous graft has been the subject of great debate for clinicians worldwide. In this paper, we reviewed the current literature on the timing of first cannulation of arteriovenous grafts. METHODS Searches of PubMed, Medline and the Cochrane Library were performed using specific search terms to identify articles, dealing primarily with the timi...
متن کاملOne-year efficacy of expanded polytetrafluoroethylene vascular graft in eighty-three hemodialysis patients.
INTRODUCTION Our aim was to evaluate the patency and efficacy of expanded Polytetrafluoroethylene (ePTFE) vascular graft in hemodialysis patients. MATERIALS AND METHODS In a prospective study from January 1999 to January 2001 at Sina hospital 41 patients underwent implantation of 6-mm vascular grafts and 42 underwent implantation of 8-mm grafts in order to make vascular assess for hemodialysi...
متن کاملThe effect of a recombinant elastin-mimetic coating of an ePTFE prosthesis on acute thrombogenicity in a baboon arteriovenous shunt.
A recombinant elastin-mimetic triblock protein polymer with an inverse transition temperature (approximately 20 degrees C) was used to impregnate small-diameter (4 mm i.d.) expanded polytetrafluoroethylene (ePTFE) vascular grafts. Scanning electron microscopy confirmed that initial elastin impregnation of the graft followed by further multilayer coating with elastin films filled in the fibril a...
متن کامل