Simultaneous integrated boost intensity-modulated radiotherapy versus 3-dimensional conformal radiotherapy in preoperative concurrent chemoradiotherapy for locally advanced rectal cancer

نویسندگان

  • Bong Kyung Bae
  • Min Kyu Kang
  • Jae-Chul Kim
  • Mi Young Kim
  • Gyu-Seog Choi
  • Jong Gwang Kim
  • Byung Woog Kang
  • Hye Jin Kim
  • Soo Yeun Park
چکیده

PURPOSE To evaluate the feasibility of simultaneous integrated boost intensity-modulated radiotherapy (SIB-IMRT) for preoperative concurrent chemoradiotherapy (PCRT) in locally advanced rectal cancer (LARC), by comparing with 3-dimensional conformal radiotherapy (3D-CRT). MATERIALS AND METHODS Patients who were treated with PCRT for LARC from 2015 January to 2016 December were retrospectively enrolled. Total doses of 45 Gy to 50.4 Gy with 3D-CRT or SIB-IMRT were administered concomitantly with 5-fluorouracil plus leucovorin or capecitabine. Surgery was performed 8 weeks after PCRT. Between PCRT and surgery, one cycle of additional chemotherapy was administered. Pathologic tumor responses were compared between SIB-IMRT and 3D-CRT groups. Acute gastrointestinal, genitourinary, hematologic, and skin toxicities were compared between the two groups based on the RTOG toxicity criteria. RESULTS SIB-IMRT was used in 53 patients, and 3D-CRT in 41 patients. After PCRT, no significant differences were noted in tumor responses, pathologic complete response (9% vs. 7%; p = 1.000), pathologic tumor regression Grade 3 or higher (85% vs. 71%; p = 0.096), and R0 resection (87% vs. 85%; p = 0.843). Grade 2 genitourinary toxicities were significantly lesser in the SIB-IMRT group (8% vs. 24%; p = 0.023), but gastrointestinal toxicities were not different across the two groups. CONCLUSION SIB-IMRT showed lower GU toxicity and similar tumor responses when compared with 3D-CRT in PCRT for LARC.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions

Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...

متن کامل

Volumetric modulated arc therapy with simultaneous integrated boost for locally advanced rectal cancer.

AIMS To report the feasibility of volumetric modulated arc therapy (VMAT) for neoadjuvant radiotherapy in locally advanced rectal cancer in a dose-escalation protocol and simultaneous integrated boost (SIB) approach. Moreover, the VMAT technique was compared with three-dimensional conformal radiotherapy (3D-CRT) and fixed-field intensity modulated radiotherapy (IMRT), in terms of target coverag...

متن کامل

Effect of concurrent radiotherapy and simultaneous oral capecitabine chemotherapy on locally advanced middle and lower rectal cancer

Objective: To assess the safety and efficacy of preoperative intensity-modulated radiotherapy (IMRT) with oral capecitabine in patients with locally advanced mid-low rectal cancer using a simultaneous integrated boost (SIB) of tomotherapy. Methods: Between 2012 and 2014, total Sixteen Patients with resectable locally advanced mid-low rectal cancer patients with T3 to T4 and/or N+ rectal cancer ...

متن کامل

A phase II trial of preoperative concurrent chemotherapy and dose escalated intensity modulated radiotherapy (IMRT) for locally advanced rectal cancer

Objectives: To determine the pathological response rates and toxicity and in patients with locally advanced rectal cancer treated with concurrent capecitabine and dose escalated intensity modulated radiotherapy (IMRT) Methods: Patients with stage II or III adenocarcinoma of the rectum were treated with preoperative concurrent capecitabine and IMRT. Dose of capecitabine was 825mg/m2, 5 days a we...

متن کامل

Dosimetric comparisons of VMAT, IMRT and 3DCRT for locally advanced rectal cancer with simultaneous integrated boost

PURPOSE The purpose of this study is to compare the dosimetric differences among volumetric modulated arc therapy (VMAT), fixed-field intensity modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) for the preoperative locally advanced rectal cancer (LARC). METHODS Ten LARC patients treated in our department using the simultaneous escalate strategy were retrospec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 35  شماره 

صفحات  -

تاریخ انتشار 2017