Comparison of 3 mm versus 4 mm rigid endoscope in diagnostic nasal endoscopy☆
نویسندگان
چکیده
Objective Compare nasal endoscopy with 3 mm versus conventional 4 mm rigid 30° endoscopes for visualization, patient comfort, and examiner ease. Methods Ten adults with no previous sinus surgery underwent bilateral nasal endoscopy with both 4 mm and 3 mm endoscopes (resulting in 20 paired nasal endoscopies). Visualization, patient discomfort and examiner's difficulty were assessed with every endoscopy. Sino-nasal structures were checked on a list if visualized satisfactorily. Patients rated discomfort on a standardized numerical pain scale (0-10). Examiners rated difficulty of examination on a scale of 1-5 (1 = easiest). Results Visualization with 3 mm endoscope was superior for the sphenoid ostium (P = 0.002), superior turbinate (P = 0.007), spheno-ethmoid recess (P = 0.006), uncinate process (P = 0.002), cribriform area (P = 0.007), and Valve of Hasner (P = 0.002). Patient discomfort was not significantly different for 3 mm vs. 4 mm endoscopes but correlated with the examiners' assessment of difficulty (r = 0.73). The examiner rated endoscopy with 4 mm endoscopes more difficult (P = 0.027). Conclusions The 3 mm endoscope was superior in visualizing the sphenoid ostium, superior turbinate, spheno-ethmoid recess, uncinate process, cribriform plate, and valve of Hasner. It therefore may be useful in assessment of spheno-ethmoid recess, nasolacrimal duct, and cribriform area pathologies. Overall, patients tolerated nasal endoscopy well. Though patient discomfort was not significantly different between the endoscopes, most discomfort with 3 mm endoscopes was noted while examining structures difficult to visualize with the 4 mm endoscope. Patients' discomfort correlated with the examiner's assessment of difficulty.
منابع مشابه
Advantages of Endoscopically Assisted Surgery for Attic Cholesteatoma
Combined use of an operating microscope and a middle ear endoscope seems to be helpful for selecting an appropriate surgical technique and for identifying more patients in whom cholesteatoma can be removed by a trans-canal approach alone. To investigate whether attic cholesteatoma can be treated by a trans-canal approach alone, a review was performed of patients who had undergone endoscopically...
متن کامل“Role of Rigid Nasal Endoscopy in the Diagnosis and Management of Epistaxis”
Objectives: To evaluate the various local causes for and management of epistaxis by using rigid nasal endoscope. Methods: Totally 50 patients with epistaxis were analyzed over a period of 1 year in Sri Venkateshwara ENT Institute and Bowring and Lady Curzon hospital using rigid nasal endoscope either under Local or General anesthesia. Those patients in whom, the cause for epistaxis was difficul...
متن کاملReal-Time Video-Assisted Retrieval of Airway Foreign Body in Very Young Pediatric Patients
OBJECTIVES Advancements in medical endoscopy and techniques of rigid bronchoscopy for foreign body removal have enabled higher diagnostic accuracy, reduced morbidity and precise manipulation. However, in pediatric patients, endoscope-combined forceps may be too big to fit into the small sized airway. Here we present our method of endoscope assisted rigid bronchoscopy in pediatric patients and c...
متن کاملRigid nasal endoscopy in the diagnosis and treatment of epistaxis.
BACKGROUND AND OBJECTIVES Epistaxis is one of the common symptoms encountered in the Otorhinolaryngology department. Many times the cause for epistaxis is not found on anterior and posterior rhinoscopy. The present study was undertaken to assess the role of rigid nasal endoscope in the diagnosis and treatment of epistaxis, where normal anterior and posterior rhinoscopy did not reveal any specif...
متن کاملClinical Experience With a New Type of Rhino-Larynx Electronic Endoscope PENTAX VNL-1530
We observed recordings of pictures obtained from patients with diseases of the larynx by using a new type of rhino-larynx electronic endoscope, PENTAXVNL-1530 connected to a video processor, PENTAX EPM-3300 (Asahi Optical Co., Ltd.). The electronic endoscope differs from the fiberoptic endoscope in that it contains a small light-sensitive charge coupled device (CCD) chip that is attached to the...
متن کامل