Brain death confirmed by Tc(99m) DTPA scan in a case of subarachnoid haemorrhage following a krait bite.

نویسندگان

  • B M A C Balasuriya
  • D Nanayakara
  • C D A Goonasekara
چکیده

Brain death is defined as the cessation of cerebral and brainstem function. It is a clinical diagnosis made on the results of a series of brainstem reflex testing, in the absence of endogenous or exogenous poisons, toxins and hypothermia confounding the clinical picture. It is known that certain chemical agents in snake toxin can alter the neuronal function mimicking brainstem death. In such situations, an objective method of demonstrating brainstem death becomes essential. The demonstration of lack of cerebral perfusion is the diagnostic criterion for brain death. Here we discuss a case of brain death confirmed by a reliable and quick method using Tc 99m DTPA cerebral perfusion scan following a krait bite.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the individual renal function in chronic unilateral renal obstruction using functional CT as compared to 99mTc-DTPA renal scan

Introduction: The selection of   optimal treatment of obstructive nephrouropathy requires information about the functional status of each kidney. Nuclear renal scanning objectively measure differential renal function, multiple studies have demonstrated the role of assessment of renal perfusion and GFR with triphasic CT. The aim of this study is to assess the role of CT based on renal parenchyma...

متن کامل

Incidental finding of an incisional hernia In the 99m Tc-DTPA renal scan of a transplant recepient [Persian]

Abdominal wall hernias are the most common situations requiring major surgeries. In this study, we report a large incisional hernia, as an incidental finding, in a Tc-DTPA scan of a renal transplant recepient. Increased flow of activity in dynamic phase and relatively increased and nonuniform tracer accumulation in static phase of the study were observed.

متن کامل

Optimization of Gate’s technique for measurement of GFR during routine renal scan [Persian]

Using Gate’s technique for GFR measurement with Gamma camera, the patient is received 5mCi of Tc-99m-DTPA. By this amount of radioactivity, good quality renal scan is not possible. This study tries to optimize Gate’s technique for GFR measurement during routine renal scan (with 10-15 mCi). Methods and materials: Scanning was performed for 60 seconds from samples of Tc-99m with activities ...

متن کامل

Massive hepatomegaly in 99mTc-octreotide scintigraphy: The value of 99mTc-sulfur colloid scan

99mTc-octreotide scintigraphy, performed during the following up a 58-year old man with neuroendocrine tumor demonstrated massive hepatomegaly demonstrating multiple areas of increased and decreased uptake. Due to severe hepatomegaly concurrence of any other abdominal soft tissue lesions could not be excluded. A 99mTc-sulfur colloid scan was done and thoroughly compared wi...

متن کامل

Giant cavernous hemangioma on Tc-99m RBC scan

   A 36-year-old woman with right upper quadrant abdominal pain since three months previously and no other significant medical history was referred for evaluation of an abdominal mass. Upon clinical examination, a large palpable mass in the mid -upper abdominal area was noted. Abdominal ultrasound and spiral CT-scan showed a large hepatic mass in the left liver lobe. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Ceylon medical journal

دوره 50 4  شماره 

صفحات  -

تاریخ انتشار 2005