High-performance liquid affinity chromatography: rapid immunoanalysis of transferrin in serum.

نویسندگان

  • S Ohlson
  • B M Gudmundsson
  • P Wikström
  • P O Larsson
چکیده

We describe a new method for quantitatively measuring substances of clinical interest by high-performance liquid affinity chromatography (HPLAC). As a model system we selected analysis for transferrin in human serum with immobilized antibodies in a high-performance liquid chromatographic system. SelectiSpher-10 Activated Tresyl columns (5 or 10 x 0.5 cm) were used for in situ coupling of polyclonal antibodies to transferrin. The amount of transferrin eluted was determined by integrating the eluted peak at 280 nm. The whole analytical procedure--including injection of sample, washing, elution, and analysis of data--takes only 7 min. We characterized the HPLAC system for analysis of transferrin in several ways: intra-assay CV approximately 3%; inter-assay CV 2-9%; linear response up to 1 mg/mL column volume; detection limit approximately 3 micrograms; analytical recovery 98% +/- 2%; purity of eluted sample greater than 95% (SDS-PAGE). The HPLAC method was compared with "rocket" immunoelectrophoresis, a commonly used method of analysis for transferrin, and there was excellent correlation between the two methods (r = 0.96, n = 60). Benefits of this HPLAC technique include high precision, rapid analysis, and simplified sample handling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preparation and Characterisation of Immunoadsorbents for High Performance Liquid Affinity Chromatography (HPLAC)

The efficacy of activation methods and coupling were studied in the context of performance in batch and fixed bed binding experiments utilizing cell culture fluids or blood plasma as feedstock. Conclusions were drawn regarding selection of solid phase according to pore size, rigidity, pH stability, Chemistry of derivation and activation, and gross concentration of immobilized ligand require...

متن کامل

Non-transferrin-bound iron in plasma or serum from patients with idiopathic hemochromatosis. Characterization by high performance liquid chromatography and nuclear magnetic resonance spectroscopy.

The nature of non-transferrin-bound iron in the plasma or serum of iron-overloaded hemochromatosis patients was studied by high performance liquid chromatography (HPLC) and high resolution nuclear magnetic resonance (NMR). 500-MHz proton Hahn spin-echo NMR spectra of plasma or serum, combined with the use of the iron chelator desferrioxamine, suggests complexation of iron ions with citrate and ...

متن کامل

Disialo-trisialo bridging of transferrin is due to increased branching and fucosylation of the carbohydrate moiety.

BACKGROUND Carbohydrate deficient transferrin (CDT) is used for detection of alcohol abuse and follow-up. High performance liquid chromatography (HPLC) of transferrin glycoforms is highly specific for identification of alcohol abuse, but unresolved disialo- and trisialotransferrin glycoforms sometimes makes interpretation difficult. The cause of this phenomenon is unknown, cannot be explained b...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 34 10  شماره 

صفحات  -

تاریخ انتشار 1988