Using ventilator graphics to identify patient-ventilator asynchrony.

نویسندگان

  • Jon O Nilsestuen
  • Kenneth D Hargett
چکیده

Patient-ventilator interaction can be described as the relationship between 2 respiratory pumps: (1) the patient's pulmonary system, which is controlled by the neuromuscular system and influenced by the mechanical characteristics of the lungs and thorax, and (2) the ventilator, which is controlled by the ventilator settings and the function of the flow valve. When the 2 pumps function in synchrony, every phase of the breath is perfectly matched. Anything that upsets the harmony between the 2 pumps results in asynchrony and causes patient discomfort and unnecessarily increases work of breathing. This article discusses asynchrony relative to the 4 phases of a breath and illustrates how asynchrony can be identified with the 3 standard ventilator waveforms: pressure, flow, and volume. The 4 phases of a breath are: (1) The trigger mechanism (ie, initiation of the inspiration), which is influenced by the trigger-sensitivity setting, patient effort, and valve responsiveness. (2) The inspiratory-flow phase. During both volume-controlled and pressure-controlled ventilation the patient's flow demand should be carefully evaluated, using the pressure and flow waveforms. (3) Breath termination (ie, the end of the inspiration). Ideally, the ventilator terminates inspiratory flow in synchrony with the patient's neural timing, but frequently the ventilator terminates inspiration either early or late, relative to the patient's neural timing. During volume-controlled ventilation we can adjust variables that affect inspiratory time (eg, peak flow, tidal volume). During pressure-controlled or pressure-support ventilation we can adjust variables that affect when the inspiration terminates (eg, inspiratory time, expiratory sensitivity). (4) Expiratory phase. Patients with obstructive lung disease are particularly prone to developing intrinsic positive end-expiratory pressure (auto-PEEP) and therefore have difficulty triggering the ventilator. Bedside evaluation for the presence of auto-PEEP should be routinely performed and corrective adjustments made when appropriate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Patient–ventilator asynchrony during conventional mechanical ventilation in children

BACKGROUND We aimed (1) to describe the characteristics of patient-ventilator asynchrony in a population of critically ill children, (2) to describe the risk factors associated with patient-ventilator asynchrony, and (3) to evaluate the association between patient-ventilator asynchrony and ventilator-free days at day 28. METHODS In this single-center prospective study, consecutive children ad...

متن کامل

Cycling of the mechanical ventilator breath.

Patient-ventilator interaction is a key element in optimizing mechanical ventilation. The change from inspiration to expiration is a crucial point in the mechanically ventilated breath, and is termed "cycling." Patient-ventilator asynchrony may occur if the flow at which the ventilator cycles to exhalation does not coincide with the termination of neural inspiration. Ideally, the ventilator ter...

متن کامل

Ventilator graphics and respiratory mechanics in the patient with obstructive lung disease.

Obstruction of the large and small airways occurs in several diseases, including asthma, chronic obstructive pulmonary disease, cystic fibrosis, bronchiectasis, and bronchiolitis. This article discusses the role of ventilator waveforms in the context of factors that contribute to the development of respiratory failure and acute respiratory distress in patients with obstructive lung disease. Dis...

متن کامل

How often does patient-ventilator asynchrony occur and what are the consequences?

Mechanical ventilation can be life-saving for patients with acute respiratory failure. In between the 2 extremes of complete and no ventilatory support, both patient and machine contribute to ventilatory work. Ideally, ventilator gas delivery would perfectly match patient demand. This patient-ventilator interaction depends on how the ventilator responds to patient respiratory effort and, in tur...

متن کامل

Asynchrony and dyspnea.

Patient-ventilator synchrony and patient comfort are assumed to go hand in hand, yet few studies provide support for this common sense idea. In reality, synchrony between the patient and ventilator is complex and can be affected by the ventilator settings, type of ventilator, patient-ventilator interface, and sedation. Inspections of airway pressure and flow waveforms are reliable methods for d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 50 2  شماره 

صفحات  -

تاریخ انتشار 2005