The determination of linear and angular penetration of the femoral head into the acetabular component as an assessment of wear in total hip replacement: a comparison of four computer-assisted methods.
نویسندگان
چکیده
We have compared four computer-assisted methods to measure penetration of the femoral head into the acetabular component in total hip replacement. These were the Martell Hip Analysis suite 7.14, Rogan HyperOrtho, Rogan View Pro-X and Roman v1.70. The images used for the investigation comprised 24 anteroposterior digital radiographs and 24 conventional acetate radiographs which were scanned to provide digital images. These radiographs were acquired from 24 patients with an uncemented total hip replacement with a follow-up of approximately eight years (mean 8.1; 6.3 to 9.1). Each image was measured twice by two blinded observers. The mean annual rates of penetration of the femoral head measured in the eight-year single image analysis were: Martell, 0.24 (SD 0.19); HyperOrtho, 0.12 (SD 0.08); View Pro-X, 0.12 (SD 0.06); Roman, 0.12 (SD 0.07). In paired analysis of the six-month and eight-year radiographs: Martell, 0.35 (SD 0.22); HyperOrtho, 0.15 (SD 0.13); View Pro-X, 0.11 (SD 0.06); Roman, 0.11 (SD 0.07). The intra- and inter-observer variability for the paired analysis was best for View Pro-X and Roman software, with intraclass correlations of 0.97, 0.87 and 0.96, 0.87, respectively, and worst for HyperOrtho and Martell, with intraclass correlations of 0.46, 0.13 and 0.33, 0.39, respectively. The Roman method proved the most precise and the most easy to use in clinical practice and the software is available free of charge. The Martell method showed the lowest precision, indicating a problem with its edge detection algorithm on digital images.
منابع مشابه
پارامترهای آناتومیک مفصل هیپ و ارتباط آنها با پارامترهای فیزیکی بدن
Background and Objective: Arthrosis of the hip joint is one of the most common complications of patients and many efforts have been made to find its etiology. One of the subjects important for researchers is morphologic parameters of the hip joint and its relationship with osteoarthritis of this joint. Since these parameters themselves are affected by physical parameters of the body and the rac...
متن کاملPatient-specific hip geometry has greater effect on THA wear than femoral head size.
In vivo linear penetration in total hip arthroplasty (THA) exhibits similar values for 28mm and 32mm femoral head diameter with considerable variations between and within the studies. It indicates factors other than femoral head diameter influence polyethylene wear. This study is intended to test the effect of patient׳s individual geometry of musculoskeletal system, acetabular cup orientation, ...
متن کاملValidation of a 3D CT method for measurement of linear wear of acetabular cups
BACKGROUND We evaluated the accuracy and repeatability of a 3D method for polyethylene acetabular cup wear measurements using computed tomography (CT). We propose that the method be used for clinical in vivo assessment of wear in acetabular cups. MATERIAL AND METHODS Ultra-high molecular weight polyethylene cups with a titanium mesh molded on the outside were subjected to wear using a hip sim...
متن کاملHip Arthroplasty and its Revision in a Child: Case Report and Literature Review
Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...
متن کاملAn Improved Technique Using the Martell Method with Ellipse Fitting: a Comparitive Study Using a Minimum 5 Year Follow-up of Highly Cross-linked Polyethylene
+*Bragdon, C.R; *Greene, M.E; **Martell, J.M; *Geller, J.A.; Kwong, M; *Harris, W.H.; *Malchau, H. +*Orthopaedic Biomechanics and Biomaterials Laboratory, Massachusetts General Hospital, Boston, MA 02114 617-726-3869 fax: 617-726-3883 [email protected] Introduction Highly cross-linked polyethylene has been used as the bearing surface of total hip arthroplasty for over 6 years. Several repor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 90 7 شماره
صفحات -
تاریخ انتشار 2008