Air sampling at the chest and ear as representative of the breathing zone.

نویسندگان

  • S E Guffey
  • M E Flanagan
  • G van Belle
چکیده

Tracer gas concentrations were measured on a 60%-sized mannequin holding a pure sulfur hexafluoride source in its hands at waist height while it stood in a wind tunnel. Samplers were placed at the mannequin's mouth, in front of the ear, and at three chest locations at lapel level. Simultaneous 15-min time-weighted average samples were taken by drawing air into different sampling bags with sampling pumps. For the factorial study design, test conditions included cross-draft velocities of 10, 22, 47, and 80 ft/min; three mannequin orientations (facing to, side to, and back to cross-draft), and rotating speed through an 80 degrees arc (fast, slow, and no movement). Each study condition was tested twice. Concentrations at all sampling locations when the mannequin faced to the front and side were less than a tenth of the levels measured at the nose (Cnose) when the mannequin faced downstream. Higher velocities significantly increased concentration at the Back orientation and generally reduced it at the Side and Facing orientations. Concentrations at the nose were different from concentrations at other sites. For 34 of 36 samples the mean chest concentration (Cchest,) was higher than the Cnose (geometric mean three times higher). The ratio of ear (Cear) and Cnose varied with orientation. At the Back orientation, Cear, was lower than Cnose, whereas Cear was higher than Cnose at the Side and Facing to flow orientations. Velocity affected the ratios of concentrations. At the Back orientation, the chest sampler provided lower overestimates of Cnose, at higher velocities than at lower values. Mannequin movement, done only at the Back orientation, proved important only for the ear location. Results showed significant and substantial differences between concentrations at the nose and lapel. However, these findings should be interpreted with caution because a very dense tracer gas and an unheated, nonbreathing mannequin were used. In more realistic conditions, the findings probably would show far smaller differences in concentrations at different sampling sites.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارزیابی مواجهه‌ی تنفسی شاغلین کیوسک‌های روزنامه فروشی شهر تهران با هیدروکربن‌های چند حلقه‌ای آروماتیک توسط دستگاه کروماتوگرافی گازی مجهز به آشکارساز اسپکتروفتومتر جرمی

  Background and aims: Polycyclic aromatic hydrocarbons (PAHs) are a group of organic compounds that are produced during the incomplete combustion of fossil fuels and petroleum products and are widely spread in the environment. Newsagents may be exposed to urban pollutions such as polycyclic aromatic hydrocarbons. The aim of this study was to assess the breathing zone exposure of newsagents to ...

متن کامل

ارزیابی مواجهه شغلی پرسنل اتاق عمل با گاز هوشبر ایزوفلوران

Background: The Operation room personnel are exposed to anesthestic gases such as Isoflurane. The Chronic exposure to such substances will increase the risk of abortion as well as congenital malformations. In this research, we have determined the amount of exposure to isoflurane gas in operation room air and the breathing zone of operation room personnel. Methods: An analytical cross sectiona...

متن کامل

ارزیابی مواجهه شغلی لعاب کاران یک صنعت سرامیک سازی با فلزسرب درهوای منطقه تنفسی

Background and Aim: Lead is a toxic metal used in different industries and occupational and environmental exposure to it is quite likely to occur. Because of its high potential toxicity, serious damages to those exposed to it are common. Since the ceramic industry, in which lead is used, is considered a domestic industry in Iran, in this study occupational exposure of glaze workers to lead was ...

متن کامل

A New Conveyable Device for Electro-drainage of Thorax

Chest tube is a flexible plastic tube used to discharge secretion in the cavity between the lungs and chest named pleural cavity. Normally, there is a small amount of fluid in the cavity between the lungs and chest; This fluid helps the movement of lungs during breathing without abrasion. Entrance of bit of air, blood or pus because injury in the pleural cavity can prevent the lungs from fully ...

متن کامل

تنگی نفس: یافتن علت درمان علائم

Extract: most people have breathing blessing but some patients are who have struggling terribly for this breathing. This article is the first part of three section's series that tells you how diagnose and treat the breathing disorder of these patients. The situation which known to all is that you inter to patient's room and see that he/she is breathing tribally. Such situation for you as well a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AIHAJ : a journal for the science of occupational and environmental health and safety

دوره 62 4  شماره 

صفحات  -

تاریخ انتشار 2001