The Global Lung Function Initiative (GLI) Network: bringing the world’s respiratory reference values together
نویسندگان
چکیده
The Global Lung Function Initiative (GLI) Network has become the largest resource for reference values for routine lung function testing ever assembled. This article addresses how the GLI Network came about, why it is important, and its current challenges and future directions. It is an extension of an article published in Breathe in 2013 [1], and summarises recent developments and the future of the GLI Network. KEY POINTS The Global Lung Function Initiative (GLI) Network was established as a result of international collaboration, and altruism between researchers, clinicians and industry partners. The ongoing success of the GLI relies on network members continuing to work together to further improve how lung function is reported and interpreted across all age groups around the world.The GLI Network has produced standardised lung function reference values for spirometry and gas transfer tests.GLI reference equations should be adopted immediately for spirometry and gas transfer by clinicians and physiologists worldwide.The recently established GLI data repository will allow ongoing development and evaluation of reference values, and will offer opportunities for novel research. EDUCATIONAL AIMS To highlight the advances made by the GLI Network during the past 5 years.To highlight the importance of using GLI reference values for routine lung function testing (e.g. spirometry and gas transfer tests).To discuss the challenges that remain for developing and improving reference values for lung function tests.
منابع مشابه
Evaluation of the global lung function initiative 2012 reference values for spirometry in a Swedish population sample
BACKGROUND The Global Lung Function Initiative 2012 (GLI) reference values are currently endorsed by several respiratory societies but evaluations of applicability for adults resident in European countries are lacking. The aim of this study was to evaluate if the GLI reference values are appropriate for an adult Caucasian Swedish population. METHODS During 2008-2013, clinical examinations inc...
متن کاملOfficial ERS technical standards: Global Lung Function Initiative reference values for the carbon monoxide transfer factor for Caucasians.
There are numerous reference equations available for the single-breath transfer factor of the lung for carbon monoxide (T LCO); however, it is not always clear which reference set should be used in clinical practice. The aim of the study was to develop the Global Lung Function Initiative (GLI) all-age reference values for T LCOData from 19 centres in 14 countries were collected to define T LCO ...
متن کاملAge Dependency of GLI Reference Values Compared with Paediatric Lung Function Data in Two German Studies (GINIplus and LUNOKID)
A hallmark of the newly published GLI (Global Lungs Initiative) spirometric reference values is their "all-age" (3-95yr) predictive power, accomplished by incorporating non-linear age dependencies into modelling parameters. This modelling strategy is especially promising for the age range of puberty; however, the performance of GLI-values for adolescents is currently unknown. We calculated GLI-...
متن کاملImplications of adopting the Global Lungs Initiative 2012 all-age reference equations for spirometry.
The aim of this study was to determine the diagnostic and interpretative consequences of adopting the Global Lungs Initiative (GLI) 2012 spirometric prediction equations. We assessed spirometric records from 17 572 subjects (49.5% females), aged 18-85 years, from hospitals in Australia and Poland. We calculated predicted forced expiratory volume in 1 s (FEV1), forced expiratory volume (FVC), FE...
متن کاملComparison between reference values for FVC, FEV1, and FEV1/FVC ratio in White adults in Brazil and those suggested by the Global Lung Function Initiative 2012*
OBJECTIVE To evaluate the spirometry values predicted by the 2012 Global Lung Function Initiative (GLI) equations, which are recommended for international use, in comparison with those obtained for a sample of White adults used for the establishment of reference equations for spirometry in Brazil. METHODS The sample comprised 270 and 373 healthy males and females, respectively. The mean diffe...
متن کامل