A Comparison of Three Computer-based Methods Used to Determine EMG Signal Amplitude

نویسندگان

  • DOUG RENSHAW
  • MATTHEW R. BICE
  • CAMILLE CASSIDY
  • JAMES A. ELDRIDGE
  • DOUGLAS W. POWELL
چکیده

Electromyography is a commonly used method to determine relative effort and neuromuscular drive to skeletal muscle. A limitation of the interpretation of EMG within the literature is the many methods used to determine the intensity of muscle activation. In the current study, ten healthy young adults performed a level walking task while EMG was recorded from the tibialis anterior, medial gastrocnemius and fibularis longus. The EMG data were rectified and smoothed using the root mean squared (RMS). Peak RMS (pRMS), mean RMS (mRMS) and integrated EMG (iEMG) were normalized to the peak value within the subject and were used to determine EMG amplitude. A 3×3 repeated measures analysis of variance was used to determine significant differences between the methods of determining EMG amplitude. The findings of the current study show that pRMS produced significantly lower EMG amplitudes than mRMS or iEMG values. Furthermore, mRMS and iEMG produced nearly identical normalized EMG amplitudes. Based on the findings of this study and the components of each measurement of EMG amplitude, it is suggested to use mRMS to determine EMG amplitude.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

EMG-based Fatigue Assessment During Endurance Testing With Different VT Protocols

BACKGROUND: Muscle fatigue can be defined as the failure of a muscle to maintain a reasonably expected force output. The multivariate approach to fatigue assessment is used because the multiple (EMG) feature provides more information than anyone. OBJECTIVE: This study presents a method of assessing muscle fatigue during endurance testing at 50% maximal voluntary contraction (MVC) using electro...

متن کامل

Extraction of Respiratory Signal Based on Image Clustering and Intensity Parameters at Radiotherapy with External Beam: A Comparative Study

Background: Since tumors located in thorax region of body mainly move due to respiration, in the modern radiotherapy, there have been many attempts such as; external markers, strain gage and spirometer represent for monitoring patients’ breathing signal. With the advent of fluoroscopy technique, indirect methods were proposed as an alternative approach to extract patients’ breathing signals...

متن کامل

معرفی روش استفاده از سیگنال مکانومیوگرام در ارزیابی عملکرد عضلات

  Background and aims   Recordings of electrical activity in the muscle and surface electromyography (EMG) have been widely used in the field of applied physiology. In parallel to  recording of the EMG, the detectable low-frequency vibration signal generated by the skeletal  muscle has been known and well documented. As the nature of the signal has been progressively   revealed, the term of mec...

متن کامل

The Usability and Efficiency Human-Computer Interface in Cervical Spinal Cord injury by Game-based Electromyography Biofeedback and EMG Biofeedback

Background and Aims: The purpose of this study was to compare the efficacy and usability of human-computer interface in cervical spinal cord injury with two computer games based and EMG biofeedback. Methods: The sample size was 20 participants (healthy and spinal cervical lesions) who were selected as available. The statistical population of the study was spinal cord injury patients referred t...

متن کامل

Quantitative Assessment of Muscle Fatigue for FES Research Studies

Background: Muscle fatigue is an important issue in neuromuscular rehabilitation. Better control of this phenomenon would result in better prevention of its consequent physiological damages.Objective: To provide a mathematical representation of muscle fatigue as a function of time.Methods: We conducted this study by combining the EMG-based estimation methods of muscle activation with the availa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2010