Disinfection of the hospital water supply: a hidden risk to dialysis patients
نویسنده
چکیده
Water suitable for drinking is unsuited for use in the preparation of haemodialysis fluid and undergoes additional treatment. The primary component of the additional treatment is reverse osmosis, which does not remove low-molecular-weight contaminants, and the water treatment system must contain carbon beds or filters to ensure effective removal of such contaminants. The recent article by Bek and colleagues highlights an unrecognised issue with respect to chemicals that may be added to the water within hospitals to ensure that the distribution network is free of pathogens (for example, Legionella, pseudomonas, and mycobacteria) and underlines the need for personnel responsible for dialysis in a renal or intensive care setting to be aware of any potential effects that disinfection of the hospital water treatment system may have on the product water used in the preparation of dialysis fluid. Such awareness requires communication and the sharing of information between clinical and facilities staff.
منابع مشابه
Methemoglobinemia in critically ill patients during extended hemodialysis and simultaneous disinfection of the hospital water supply
INTRODUCTION To evaluate the cause of methemoglobinemia in patients undergoing extended daily hemodialysis/hemodiafiltration we analyzed the relationship between methemoglobinemia and the water disinfection schedule of the hospital. METHODS We reviewed all arterial blood gas analyses, obtained over a one-year period, in patients undergoing extended hemodialysis/hemodiafiltration, and compared...
متن کاملInvestigation of Legionella Pneumophila bacteria in hospital water supply systems
Introduction: Legionella Pneumophila bacteria is known as one of the most important nosocomial infections and the most common cause of death in patients. This study was aimed to identify Legionella Pneumophila bacteria in hospital water supply systems. Material and Methods: This descriptive cross-sectional study was performed to identify Legionella pneumophila in hot and cold-water systems of i...
متن کاملDEVELOPMENT OF A METHOD FOR ALUMINIUM DETERMINATION IN SERUM AND DIALYSIS FLUID BY FLAMELESS ATOMIC ABSORPTION WITH GRAPHITE FURNACE
Aluminium determination was carried out in serum and dialysis fluid by a simple and reliable method of nameless atomic absorption with graphite furnace . . No preparatory procedures are required for water and dialysis fluid. In this method serum was mixed with 0.2% HNO, to allow complete combustion of the samples in order to improve analytical precision. The method has a sensitivity of 15 p...
متن کاملPrevalence of hepatitis C, hepatitis B, and HIV infection among hemodialysis patients in Jenin District (Palestine)
Background and Aims: End-stage renal disease patients treated by hemodialysis (HD) are more susceptible for infection by viral hepatitis and human immunodeficiency virus (HIV) infections. Infection by these viruses is promoted by the characteristic immunological dysfunction that develops in renal failure and interferes with the patient's ability to eliminate these viruses. Prevalence of these v...
متن کاملRisk of hospital-acquired legionnaires' disease in cities using monochloramine versus other water disinfectants.
OBJECTIVE To measure the association between the disinfection of municipal drinking water with monochloramine and the occurrence of hospital-acquired legionnaires' disease (LD). SETTING One hundred sixty-six U.S. hospitals. DESIGN Survey of 459 members of the Society for Healthcare Epidemiology of America (SHEA) for hospital features; endemic- and outbreak-related, hospital-acquired LD; the...
متن کامل