Katsevich-Type Algorithms for Variable Radius Spiral Cone-Beam CT
نویسندگان
چکیده
To solve the long object problem, an exact and efficient algorithm has been recently developed by Katsevich. While the Katsevich algorithm only works with standard helical cone-beam scanning, there is an important need for nonstandard spiral cone-beam scanning. Specifically, we need a scanning spiral of variable radius for our newly proposed electron-beam CT/micro-CT prototype. In this paper, for variable radius spiral cone-beam CT we construct two Katsevich-type cone-beam reconstruction algorithms in the filtered backprojection (FBP) and backprojected filtration (BPF) formats, respectively. The FBP algorithm is developed based on the standard Katsevich algorithm, and consists of four steps: data differentiation, PI-line determination, slant filtration and weighted backprojection. The BPF algorithm is designed based on the scheme by Zou and Pan, and also consists four steps: data differentiation, PI-line determination, weighted backprojection and inverse Hilbert transform. Numerical experiments are conducted with mathematical phantoms
منابع مشابه
Numerical studies on Feldkamp-type and Katsevich-type algorithms for cone-beam scanning along nonstandard spirals
In this paper, we perform numerical studies on Feldkamp-type and Katsevich-type algorithms for cone-beam reconstruction with a nonstandard spiral locus to develop an electron-beam micro-CT scanner. Numerical results are obtained using both the approximate and exact algorithms in terms of image quality. It is observed that the two algorithms produce similar quality if the cone angle is not large...
متن کاملStudies on implementation of the Katsevich algorithm for spiral cone-beam CT
Recently, Katsevich proposed the first exact helical cone-beam reconstruction algorithm that takes longitudinally truncated data collected from part of a scanning turn. A key theoretical basis is that any point inside the scanning helix belongs to one and only one PI-line. Unfortunately, he only provided a general formulation and did not describe the implementation details. To make this complic...
متن کاملGeometric studies on variable radius spiral cone-beam scanning.
The goal is to perform geometric studies on cone-beam CT scanning along a three-dimensional (3D) spiral of variable radius. First, the background for variable radius spiral cone-beam scanning is given in the context of electron-beam CT/micro-CT. Then, necessary and sufficient conditions are proved for existence and uniqueness of PI lines inside the variable radius 3D spiral. These results are n...
متن کاملA general inversion formula for cone beam CT
We present a new cone beam inversion formula based on a general weighting function n. The formula is theoretically exact and is represented by a 2D integral. If the source trajectory C is complete (and satisfies two other very mild assumptions), then the simplest uniform weight gives a convolution-based FBP algorithm. This choice is not always optimal from the practical point of view. The unifo...
متن کاملExact image reconstruction on PI-lines from minimum data in helical cone-beam CT.
The development of accurate and efficient algorithms for image reconstruction from helical cone-beam projections remains a subject of active research. In the last few years, a number of quasi-exact and exact algorithms have been developed. Among them, the Katsevich algorithms are of filtered backprojection type and thus possess computational advantages over other existing exact algorithms. In t...
متن کامل