In vivo NMR of hyperpolarized 3He in the human lung at very low magnetic fields.
نویسندگان
چکیده
We present NMR measurements of the diffusion of hyperpolarized 3He in the human lung performed at fields much lower than those of conventional MRI scanners. The measurements were made on standing subjects using homebuilt apparatus operating at 3mT. O(2)-limited transverse relaxation (T(2) up to 15-35s) could be measured in vivo. Accurate global diffusion measurements have been performed in vivo and in a plastic bag; the average apparent diffusion coefficient (ADC) in vivo was 14.2+/-0.6mm(2)/s, whereas the diffusion coefficient in the bag (3He diluted in N(2)) was 79.5+/-1mm(2)/s. 1D ADC mapping with high SNR ( approximately 200-300) demonstrates the real possibility of performing quality lung imaging at extremely low fields.
منابع مشابه
In-Vivo NMR of Hyperpolarized He in the Human Lung at Very Low Magnetic Fields
We present NMR measurements of the diffusion of hyperpolarized 3He in the human lung performed at fields much lower than those of conventional MRI scanners. The measurements were made on standing subjects using homebuilt apparatus operating at 3 mT. O2-limited transverse relaxation (T2 up to 15-35 s) could be measured in-vivo. Accurate global diffusion measurements have been performed in-vivo a...
متن کاملAn open-access, very-low-field MRI system for posture-dependent 3He human lung imaging.
We describe the design and operation of an open-access, very-low-field, magnetic resonance imaging (MRI) system for in vivo hyperpolarized 3He imaging of the human lungs. This system permits the study of lung function in both horizontal and upright postures, a capability with important implications in pulmonary physiology and clinical medicine, including asthma and obesity. The imager uses a bi...
متن کاملHyperpolarized Gas Polarimetry and Imaging at Low Magnetic Field
MR imaging with polarized noble gases has shown promise in both, biomedical and material’s imaging applications. Its advantage over the conventional proton MRI lies in its ability to produce high signal-to-noise ratio (SNR), high-resolution images at low magnetic field strengths. In this work: 1. We implemented and studied in detail two methods for detecting hyperpolarization levels of 129Xe an...
متن کاملMRI of the lung gas-space at very low-field using hyperpolarized noble gases.
In hyperpolarized (HP) noble-gas magnetic resonance imaging, large nuclear spin polarizations, about 100,000 times that ordinarily obtainable at thermal equilibrium, are created in 3He and 129Xe. The enhanced signal that results can be employed in high-resolution MRI studies of void spaces such as in the lungs. In HP gas MRI the signal-to-noise ratio (SNR) depends only weakly on the static magn...
متن کاملImaging lung microstructure in mice with hyperpolarized 3He diffusion MRI.
Quantitative measurement of lung microstructure is of great significance in assessment of pulmonary disease, particularly in the earliest stages. The technique for MRI-based 3He lung morphometry was previously developed and validated for human lungs, and was recently extended to ex vivo mouse lungs. The technique yields accurate, quantitative information about the microstructure and geometry of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance
دوره 162 1 شماره
صفحات -
تاریخ انتشار 2003