Evaluation of nine automated high-sensitivity C-reactive protein methods: implications for clinical and epidemiological applications. Part 2.

نویسندگان

  • W L Roberts
  • L Moulton
  • T C Law
  • G Farrow
  • M Cooper-Anderson
  • J Savory
  • N Rifai
چکیده

BACKGROUND C-Reactive protein (CRP) can provide prognostic information about risk of future coronary events in apparently healthy subjects. This application requires higher sensitivity assays than have traditionally been available in the clinical laboratory. METHODS Nine high-sensitivity CRP (hs-CRP) methods from Dade Behring, Daiichi, Denka Seiken, Diagnostic Products Corporation, Iatron, Kamiya, Olympus, Roche, and Wako were evaluated for limit of detection, linearity, precision, prozone effect, and comparability with samples from 388 apparently healthy individuals. RESULTS All methods had limits of detection that were lower than the manufacturers' claimed limit of quantification except for the Kamiya, Roche, and Wako methods. All methods were linear at 0.3-10 mg/L. The Diagnostic Products Corporation, Kamiya, Olympus, and Wako methods had imprecision (CVs) >10% at 0.15 mg/L. The Iatron, Olympus, and Wako methods demonstrated prozone effects at hs-CRP concentrations of 12, 206, and 117 mg/L, respectively. hs-CRP concentrations demarcating each quartile in a healthy population were method-dependent. Ninety-two to 95% of subjects were classified into the same quartile of hs-CRP established by the Dade Behring method by the Denka Seiken, Diagnostic Products Corporation, Iatron, and Wako methods. In contrast, 68-77% of subjects were classified into the same quartile by the Daiichi, Kamiya, Olympus, and Roche methods. No subject varied by more than one quartile by any method. CONCLUSIONS Four of the nine examined hs-CRP methods classified apparently healthy subjects into quartiles of hs-CRP similar to the classifications assigned by the comparison method. Additional standardization efforts are required because an individual patient's results will be interpreted using population-based cutpoints.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Counterpoint: Food and Drug Administration guidance for C-reactive protein assays: matching claims with performance data.

LM, et al. CDC/AHA workshop on markers of inflammation and cardiovascular disease: application to clinical and public health practice: report from the laboratory science discussion group. Circulation 2004;110:e545–9. 4. Ridker PM, Wilson PW, Grundy SM. Should C-reactive protein be added to metabolic syndrome and to assessment of global cardiovascular risk? Circulation 2004;109:2818–25. 5. US Fo...

متن کامل

Distributions of C-reactive protein measured by high-sensitivity assays in apparently healthy men and women from different populations in Europe.

A, et al. C-reactive protein, a sensitive marker of inflammation, predicts future risk of coronary heart disease in initially healthy middle-aged men: results from the Plasma concentration of C-reactive protein and risk of ischemic stroke and transient ischemic attack: the Framingham study. Prospective study of C-reactive protein, homocysteine, and plasma lipid levels as predictors of sudden ca...

متن کامل

Relationships of Serum Level of High- Sensitivity C- Reactive Protein (hs- CRP) and White Blood Cell (WBC) Count with Gamma- Glutamyltransferase among Iranian Healthy Adults

Background & Objective: There are many common infections and inflammations among people over the world. This demands an affordable and reliable test with high sensitivity/specificity to predict or confirm the diagnosis of such cases in routinely clinical practice. In the present study, we aimed to find any potential correlation between serum levels of GGT and CRP- Q and/or hs- CRP and ...

متن کامل

Flexibility of melting temperature assay for rapid detection of insertions, deletions, and single-point mutations of the AGXT gene responsible for type 1 primary hyperoxaluria.

opening the door to a less expensive automated method with similar sensitivity and a wide measuring range. For practical use, it is essential to obtain microparticle reagents colloidally stable under reaction and storage conditions, with the stability often depending on protein coverage. Colloidal particles coated with polyclonal IgG usually are not very stable, mainly because of the high antib...

متن کامل

Evaluation of four automated high-sensitivity C-reactive protein methods: implications for clinical and epidemiological applications.

BACKGROUND C-reactive protein (CRP) can provide prognostic information about the risk of developing atherosclerotic complications in apparently healthy patients. This new clinical application requires quantification of CRP concentrations below those traditionally measured in the clinical laboratory. METHODS The Dade Behring BN II, the Abbott IMx, the Diagnostic Products Corporation IMMULITE, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 47 3  شماره 

صفحات  -

تاریخ انتشار 2001