Insulin pumps.

نویسندگان

  • T Torrance
  • V Franklin
  • S Greene
چکیده

I nsulin pump therapy—continuous subcutaneous insulin infusion (CSII)—was developed in the UK in the 1970s. Rapid technological developments changed the initial pumps from the size of a house brick, charged by mains electricity to an acceptable dimension, battery driven. We described the use of pumps in young people with type 1 diabetes (T1D) in the UK in Archives of Disease in Childhood in the early 1980s. While countries across the world, notably the USA, continued with pump development, the UK appeared to move away from CSII, following concerns about efficacy and safety, and the potential financial burden on the NHS. In the past decade technology has advanced and modern pumps are now small in size (matchbox), reliable, available, and relatively affordable. Many countries throughout the world use CSII as part of the modern management and treatment of T1D in children and young people, and large pump centres can be found in Germany, Holland, Belgium, and Scandinavia, as well the USA. Across all ages there are currently 20 000 pumps in use in Germany and 100 000 in the United States. At present the major centres in the UK (for example, Bournemouth and Harrogate) cater for a largely adult population, with small numbers of children and young people using insulin pumps.* CSII delivers a variable preprogrammable basal rate of fast/rapid acting insulin via a small indwelling plastic cannula, with insulin delivered as a background basal rate with bolus doses to cover the intake of carbohydrate containing foods, and to correct high blood glucose levels. This system of insulin delivery appears to offer not only improvement in metabolic control, but also increased physiological and psychological wellbeing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Siphon effects on continuous subcutaneous insulin infusion pump delivery performance.

BACKGROUND The objective was to quantify hydrostatic effects on continuous subcutaneous insulin infusion (CSII) pumps during basal and bolus insulin delivery. METHODS We tested CSII pumps from Medtronic Diabetes (MiniMed 512 and 515), Smiths Medical (Deltec Cozmo 1700), and Insulet (OmniPod) using insulin aspart (Novolog, Novo Nordisk). Pumps were filled and primed per manufacturer's instruct...

متن کامل

Consensus evidence-based guidelines for use of insulin pump therapy in the management of diabetes as per Indian clinical practice.

The use of insulin pump in diabetes is likely to increase with recent advances in technology. Although the evidence for the superiority of pumps over multiple daily injections (MDI) is inconsistent, data from accumulating uncontrolled studies indicate greater reductions in glycated haemoglobin in patients switching to continuous subcutaneous insulin infusion (CSII) from MDI therapy. Due to the ...

متن کامل

Bubble formation occurs in insulin pumps in response to changes in ambient temperature and atmospheric pressure but not as a result of vibration

INTRODUCTION Bubble formation in insulin pump giving sets is a common problem. We studied change in temperature, change in atmospheric pressure, and vibration as potential mechanisms of bubble formation. METHODS 5 Animas 2020 pumps with 2 mL cartridges and Inset II infusion systems, 5 Medtronic Paradigm pumps with 1.8 mL cartridge and Quickset and 3 Roche Accu-chek pumps with 3.15 mL cartridg...

متن کامل

Continuous insulin infusion systems in type 2 diabetes.

There are various delivery devices available for insulin like syringes, pens, and insulin pumps. Syringes have drawbacks like dosage errors and pain. Insulin pumps can be useful to mimic the physiological insulin secretion. Though the insulin pumps are launched in India a decade ago, they are not popular due to high price and thus there is limited experience and queries with its use. Use of ins...

متن کامل

Comparison of rechargeable versus battery-operated insulin pumps: temperature fluctuations

The role of continuous subcutaneous insulin infusion (insulin pumps) has become increasingly important in diabetes management, and many different types of these systems are currently available. This exploratory study focused on the reported heating issues that lithium-ion battery-powered pumps may have during charging compared with battery-operated pumps. It was found that pump temperature incr...

متن کامل

Importance of manually entering blood glucose readings when wireless-compatible meters are not being used with an insulin pump.

BACKGROUND The objective was to determine if there were differences in blood glucose monitoring (BGM) data downloaded from insulin pumps of patients who use meters that wirelessly transmit data to their insulin pumps (i.e., wireless group) and those who do not (i.e., nonwireless group). METHODS Blood glucose monitoring data were downloaded from the meters and insulin pumps of 47 children and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of disease in childhood

دوره 88 11  شماره 

صفحات  -

تاریخ انتشار 2003