Ex-Vivo Evaluation of a Modified Teno Fix(®) Device Repair Pattern Versus a 3-Loop Pulley for Repair of Equine Flexor Tendons.

نویسندگان

  • Mattie A McMaster
  • Amelia S Munsterman
  • Wendi H Weimar
  • Elizabeth J Barrett
  • R Reid Hanson
چکیده

OBJECTIVE To compare the load to ultimate failure, load to a 2 mm gap, mode of failure, and gap at failure (mm) of the Teno Fix(®) (TF) to the 3-loop pulley (3LP) for repair of equine tendon lacerations. The use of 4TF devices versus 5TF devices on load to ultimate failure and load to a 2 mm gap was also compared. STUDY DESIGN Ex vivo biomechanical study; unbalanced incomplete block (horse) design. SAMPLES Cadaveric equine forelimb superficial digital flexor tendon (n = 20 paired tendons). METHODS Ten tendon pairs were selected randomly and repaired with a 3LP and 4TF pattern, and 10 tendon pairs repaired with a 3LP and 5TF pattern. Load to ultimate failure, load to a 2 mm gap, mode of failure, and gap at failure were obtained using materials testing. RESULTS The 3LP had a significantly greater ultimate load to failure (P < .001, respectively) and a significantly higher load to a 2 mm gap than both TF repairs (P < .001, respectively). The most frequent mode of failure was suture pull-out for the 3LP and anchor pull-out for the TF. Gap at failure was significantly larger in the 3LP than both TF repairs (P < .001). The ultimate load to failure was significantly higher for the 5TF than the 4TF (P = .004) but there was no significant difference in load to a 2 mm gap, or gap at failure between both TF repairs (P = .11, P = .15, respectively). CONCLUSIONS Neither TF repair was stronger than the 3LP in load to ultimate failure and load to a 2 mm gap. Addition of a fifth TF device significantly increased the load to ultimate failure but did effect the load to a 2 mm gap over the 4TF.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flexor Tendon Repair Using the Teno Fix System, 2-strand and 4-strand Sutures in Humancadavers: Work of Flexion, Strength and Stiffness

INTRODUCTION: Immediate mobilization of repaired tendons has beneficial effects on the functional outcome of the repair, in both experimental animals and clinical studies. Therefore, many techniques for improving the strength of the tendon repair have been reported. The Teno Fix system (TFS) has been devised to improve initial flexor tendon repair strength and reproducibility without having to ...

متن کامل

The Effects of Early Active Motion Rehabilitation after Teno Fixrm Tendon Repair in Zone 11 Flexor Tendon Lacerations of the Hand

The purpose of this study is to evaluate the advantages of an early active motion rehabilitation protocol after flexor tendon repair of the hand with the Teno Fix system. Patients with Zone II flexor tendon lacerations repaired with the Teno Fix system will undergo a rigorous early active motion protocol developed at the New York Orthopedic Hospital, starting post-op day 3. Each patient will be...

متن کامل

Biomechanical testing of a novel suture pattern for repair of equine tendon lacerations.

OBJECTIVE To compare in vitro biomechanical properties of a novel suture pattern to a current standard for primary repair of equine superficial digital flexor tendon (SDFT) laceration. STUDY DESIGN In vitro randomized, paired design. ANIMALS Cadaveric equine forelimb SDFT (n = 24). METHODS The 3-loop pulley (3LP) and 6-strand Savage (SSS) suture patterns were applied to transected equine ...

متن کامل

Flexor tendon repair: a comparative study between a knotless barbed suture repair and a traditional four-strand monofilament suture repair.

We compared the tensile strength of a novel knotless barbed suture method with a traditional four-strand Adelaide technique for flexor tendon repairs. Forty fresh porcine flexor tendons were transected and randomly assigned to one of the repair groups before repair. Biomechanical testing demonstrated that the tensile strengths between both tendon groups were very similar. However, less force wa...

متن کامل

Looped versus single-stranded flexor tendon repairs: a cadaveric mechanical study.

PURPOSE To compare the tensile properties of 4-strand modified Kessler flexor tendon repairs using a looped or single-stranded suture. METHODS We evaluated the mechanical properties of 4-strand Kessler zone II core suture repairs using either looped or single-stranded suture in human flexor digitorum profundus and flexor pollicis longus tendons. Forty repairs were performed on tendons from bi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Veterinary surgery : VS

دوره 44 7  شماره 

صفحات  -

تاریخ انتشار 2015