Continuous glucose monitors and the burden of tight glycemic control in critical care: can they cure the time cost?

نویسندگان

  • Matthew Signal
  • Christopher G Pretty
  • J Geoffrey Chase
  • Aaron Le Compte
  • Geoffrey M Shaw
چکیده

BACKGROUND Tight glycemic control (TGC) in critical care has shown distinct benefits but has also proven to be difficult to obtain. The risk of severe hypoglycemia (<40 mg/dl) raises significant concerns for safety. Added clinical burden has also been an issue. Continuous glucose monitors (CGMs) offer frequent automated measurement and thus the possibility of using them for early detection and intervention of hypoglycemic events. Additionally, regular measurement by CGM may also be able to reduce clinical burden. AIM An in silico study investigates the potential of CGM devices to reduce clinical effort in a published TGC protocol. METHODS This study uses retrospective clinical data from the Specialized Relative Insulin Nutrition Titration (SPRINT) TGC study covering 20 patients from a benchmark cohort. Clinically validated metabolic system models are used to generate a blood glucose (BG) profile for each patient, resulting in 33 continuous, separate BG episodes (6881 patient hours). The in silico analysis is performed with three different stochastic noise models: two Gaussian and one first-order autoregressive. The noisy, virtual CGM BG values are filtered and used to drive the SPRINT TGC protocol. A simple threshold alarm is used to trigger glucose interventions to avert potential hypoglycemia. The Monte Carlo method was used to get robust results from the stochastic noise models. RESULTS Using SPRINT with simulated CGM noise, the BG time in an 80-110 mg/dl band was reduced no more than 4.4% to 45.2% compared to glucometer sensors. Antihypoglycemic interventions had negligible effect on time in band but eliminated all recorded hypoglycemic episodes in these simulations. Assuming 4-6 calibration measurements per day, the nonautomated clinical measurements are reduced from an average of 16 per day to as low as 4. At 2.5 min per glucometer measurement, a daily saving of approximately 25-30 min per patient could potentially be achieved. CONCLUSIONS This paper has analyzed in silico the use of CGM sensors to provide BG input data to the SPRINT TGC protocol. A very simple algorithm was used for early hypoglycemic detection and prevention and tested with four different-sized intravenous glucose boluses. Although a small decrease in time in band (still clinically acceptable) was experienced with the addition of CGM noise, the number of hypoglycemic events was reduced. The reduction to time in band depends on the specific CGM sensor error characteristics and is thus a trade-off for reduced nursing workload. These results justify a pilot clinical trial to verify this study.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing Effects of Continuous Insulin Infusion with or without Subcutaneous Glargine Insulin on Glycemic Control in Diabetic Patients Undergoing Coronary Artery Bypass Graft (CABG)

OBJECTIVE: Hyperglycemia is associated with increased morbidity and mortality in diabetic patients following coronary artery bypass grafting. Tight glycemic control in perioperative period can reduce these events. The goal of this study was to determine whether combination of continuous infusion and subcutaneous glargine as a basal insulin could improve glycemic control. MATERIAL AND METHODS:...

متن کامل

Measuring and reporting glycemic control in clinical trials: building a path to consensus

Clinical trials over time have used a variety of approaches for both measuring tight glycemic control and reporting results. The review by Finfer and colleagues in this issue of Critical Care is a step toward consensus within the research community to standardize the way blood glucose is measured and reported in clinical trials. The authors propose using specific measures of central tendency an...

متن کامل

Evaluation of nursing work effort and perceptions about blood glucose testing in tight glycemic control.

BACKGROUND Tight glycemic control is important in critically ill patients and involves insulin infusions and monitoring of blood glucose levels. Hourly measurements of blood glucose levels and adjustments of intravenous insulin doses require additional work by nurses. OBJECTIVES To evaluate the nursing work incurred with and nursing perceptions about tight glycemic control and blood glucose m...

متن کامل

Tight glycemic control versus standard care after pediatric cardiac surgery.

BACKGROUND In some studies, tight glycemic control with insulin improved outcomes in adults undergoing cardiac surgery, but these benefits are unproven in critically ill children at risk for hyperinsulinemic hypoglycemia. We tested the hypothesis that tight glycemic control reduces morbidity after pediatric cardiac surgery. METHODS In this two-center, prospective, randomized trial, we enrolle...

متن کامل

Tight glycemic control in the ICU - is the earth flat?

Tight glycemic control in the ICU has been shown to reduce mortality in some but not all prospective randomized control trials. Confounding the interpretation of these studies are differences in how the control was achieved and underlying incidence of hypoglycemia, which can be expected to be affected by the introduction of continuous glucose monitoring (CGM). In this issue of Critical Care, a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 4 3  شماره 

صفحات  -

تاریخ انتشار 2010