[Correction factor for individuals with accommodative capacity based on automated refractor].

نویسندگان

  • Rodrigo Ueno Takahagi
  • Andréia Lavagnoli
  • Tatiana Moura Fernandes
  • Silvana Artioli Schelinni
  • Carlos Roberto Padovani
چکیده

PURPOSE To determine a correction factor for refractive errors evaluated without cycloplegy effect. METHODS A study was made with 623 patients (1,246 eyes) of both sexes, aging between 3 and 40 years old. The dynamic and static refractometries were obtained using the automated refractor Shin-Nippon Accuref-K 9001. 1% Cyclopentolate was dropped and the static refractometry was performed in 30 minutes. Data were analyzed using the linear regression model and the multiple regression model of the diopter values with and without cycloplegy effect according to age. RESULTS The correlation between the astigmatism diopter values with and without cicloplegy ranged from 81.52% to 92.27%. Analyzing the spherical diopter values, the correlation was lower (53.57% to 87.78%). The astigmatism axis also revealed low correlation values (28.86% to 58.80%). The multiple regression model according to age demonstrated multiple determination coefficient with high values for myopia (86.38%) and astigmatism (79.79%). The lowest multiple determination coefficient was observed for astigmatism axis (17.70%). CONCLUSION It was possible to demonstrate a high correlation in refractive errors with and without cycloplegy effect on the cylindrical ametropies. Mathematical formules, for cylindrical and spherical ametropies, were presented as a correction factor for refraction of the patients not submitted to cycloplegy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Face Detection with methods based on color by using Artificial Neural Network

The face Detection methodsis used in order to provide security. The mentioned methods problems are that it cannot be categorized because of the great differences and varieties in the face of individuals. In this paper, face Detection methods has been presented for overcoming upon these problems based on skin color datum. The researcher gathered a face database of 30 individuals consisting of ov...

متن کامل

Accommodative changes after SMILE for moderate to high myopia correction

BACKGROUND To investigate accommodative response and accommodative lag changes after femtosecond laser small incision lenticule extraction (SMILE) for moderate to high myopia correction. METHODS A total of 32 eyes of 32 patients with no strabismus who underwent SMILE were enrolled in this prospective clinical study. The accommodative response was obtained viewing monocularly with spherical eq...

متن کامل

Accommodative response and cortical activity during sustained attention

Greater accommodative lag and vergence deficits have been linked to attentional deficits similar to those observed in Attention Deficit Hyperactivity Disorder (ADHD). The purpose of the present study was to assess the effect of accommodative-vergence stress on a measure of sustained attention (Conners CPT) used in the diagnosis of ADHD. Twenty-seven normal non-ADHD adults completed the Conners ...

متن کامل

Accommodative Ability in Pre-presbyopic Diabetic Patients

Introduction: To compare various accommodative parameters in prepresbyopic diabetic patients with age-matched healthy individuals. Materials and Methods: Study population consisted of 32 younger-onset diabetic patients (30-40 years of age) and 28 age-matched healthy normal individuals. Using the best correction for distance visual acuity (20.20 by Snellen chart), multiple accommodative ability ...

متن کامل

Comparison of three monocular methods for measuring accommodative stimulus–response curves

PURPOSE The aim was to evaluate the repeatability of dynamic measurement of the accommodative stimulus-response curve (ASRC) at three different dioptric speeds using a modified instrument and its agreement with two other methods. METHODS Twenty-nine adults (23.5 ± 2.0 years) were enrolled in the study. ASRC was measured monocularly using three methods: dynamic and static measurement using a m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos brasileiros de oftalmologia

دوره 72 6  شماره 

صفحات  -

تاریخ انتشار 2009