Artifacts in plasma volume changes due to hematology analyzer-derived hematocrit.
نویسندگان
چکیده
PURPOSE This investigation quantified the effect of changes in plasma osmolality on the measurement of hematocrit (Hct) and the implications for the subsequent use of these data to calculate changes in plasma volume and application to the World Anti-Doping Agency Athlete Biological Passport. METHODS Two groups of eight male volunteers visited the laboratory after an overnight fast. In study 1, a 20-mL blood sample was collected and aliquoted into collection tubes containing saline of varying concentrations to alter the sample osmolality. In study 2, plasma osmolality was manipulated in vivo through prolonged exercise. Samples were analyzed for hemoglobin concentration and Hct using manual methods and using an automated hematology analyzer (AHA). RESULTS Changes in blood, plasma, and red cell volumes were calculated. Although AHA Hct values did not change (P = 0.652), spun packed cell volume fell progressively as the osmolality of the sample increased (P < 0.001, study 1). Consequently, there was a significant increase in apparent plasma volume as osmolality increased (P < 0.001): regression analysis revealed that a 10 mOsm·kg change in plasma osmolality produced a difference of 0.8 Hct units and a 1.6% change in plasma volume. In study 2, exercise produced a 12 ± 3 mOsm·kg increase in plasma osmolality. No difference in Hct was apparent at rest (P = 0.659), but spun packed cell volume was 1.0 ± 0.9 Hct units lower during exercise compared with AHA data (P < 0.001). There was a difference in the degree of plasma volume change calculated, with a reduction of 8.7% ± 3.4% and 11.3% ± 3.5% reported with the manual and AHA methods, respectively (P = 0.002). CONCLUSIONS Conditions or interventions that result in a marked change in plasma osmolality produce a discrepancy in Hct measured using an AHA, consequently introducing errors into any calculation of changes in plasma volume using these data. These findings may also have implications for the measurement of Hct by World Anti-Doping Agency-accredited laboratories.
منابع مشابه
Analytical artifacts in hematocrit measurements by whole-blood chemistry analyzers.
Compact analyzers suited to near-patient testing estimate hematocrit by measuring the conductivity of undiluted blood. We evaluated the accuracy of hematocrit determination of one such analyzer (Instrumentation Laboratory BGE analyzer) against an automated cell counter (EPC) and packed cell volume (PCV) microhematocrit. When specimens (n = 34) from outpatient and ward patients were analyzed wit...
متن کاملVariability in hematology and plasma indices of common carp Cyprinus carpio, associated with age, sex and hormonal treatment
The purpose of this study was to determine changes in hematological and plasma indices of Common Carp Cyprinus carpio with regard to age, sex and hormonal treatment. Sixty fish were used to assess the age factor. Also, 20 fish including female and male were assigned to determine blood indices with regard to sex and hormonal treatment. The pituitary gland extract was used as hormone for males an...
متن کاملVariability in hematology and plasma indices of common carp Cyprinus carpio, associated with age, sex and hormonal treatment
The purpose of this study was to determine changes in hematological and plasma indices of Common Carp Cyprinus carpio with regard to age, sex and hormonal treatment. Sixty fish were used to assess the age factor. Also, 20 fish including female and male were assigned to determine blood indices with regard to sex and hormonal treatment. The pituitary gland extract was used as hormone for males an...
متن کاملComparison of hematological parameters of venous and capillary blood in athletes
Vol. 1(21) TRENDS IN SPORT SCIENCES 39 Objectives. Capillary blood sampling is less invasive than venous blood sampling; it is also often used in diagnosis of athletes. The hematological parameters are useful for general health assessment and adaptation of the athlete’s body to physical activity. Methods. The study was carried out on 40 healthy athletes (21 females and 19 males). Resting venous...
متن کاملEvaluation of the pocH-100iV DIFF hematology analyzer for use in horses and cattle Evaluatie van de pocH-100iV DIFF-hematologie analyzer voor paarden- en runderbloed
The results of the analysis of equine and bovine blood samples with the automated pocH-100iV DIFF hematology analyzer were compared with the results obtained with reference methods or other analyzers (Vet ABC, Coulter Counter ZF, Coulter LH 750 analyzer). For equine blood and most parameters in bovine blood good to excellent correlations between methods and analyzers were obtained. For bovine b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medicine and science in sports and exercise
دوره 46 1 شماره
صفحات -
تاریخ انتشار 2014