An Antiwindup Approach to Power Controller Switching in an Ambient Healthcare Network

نویسندگان

  • Michael J. Walsh
  • John Barton
  • Brendan O'Flynn
  • Martin J. Hayes
  • Seán Cian O'Mathuna
  • Seyed Mohammad Mahdi Alavi
چکیده

This paper proposes a methodology for improved power controller switching in mobile Body Area Networks operating within the ambient healthcare environment. The work extends Anti-windup and Bumpless transfer results to provide a solution to the ambulatory networking problem that ensures sufficient biometric data can always be regenerated at the base station. The solution thereby guarantees satisfactory quality of service for healthcare providers. Compensation is provided for the nonlinear hardware constraints that are a typical feature of the type of network under consideration and graceful performance degradation in the face of hardware output power saturation is demonstrated, thus conserving network energy in an optimal fashion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transmission switching cost modeling and determination candidate Lines for participation in joint energy and reserve markets

There is a great resolution calling for smart grids in recent years. Introduction of new technologies, that make the network flexible and controllable, is a main part of smart grid concept and a key factor to its success. Transmission network as a part of system network has drawn less attention. Transmission switching as a transmission service can release us from load shedding and remove the co...

متن کامل

A New Recurrent Fuzzy Neural Network Controller Design for Speed and Exhaust Temperature of a Gas Turbine Power Plant

In this paper, a recurrent fuzzy-neural network (RFNN) controller with neural network identifier in direct control model is designed to control the speed and exhaust temperature of the gas turbine in a combined cycle power plant. Since the turbine operation in combined cycle unit is considered, speed and exhaust temperature of the gas turbine should be simultaneously controlled by fuel command ...

متن کامل

Optimal Self-healing of Smart Distribution Grids Based on Spanning Trees to Improve System Reliability

In this paper, a self-healing approach for smart distribution network is presented based on Graph theory and cut sets. In the proposed Graph theory based approach, the upstream grid and all the existing microgrids are modeled as a common node after fault occurrence. Thereafter, the maneuvering lines which are in the cut sets are selected as the recovery path for alternatives networks by making ...

متن کامل

Speed Control of Permanent Magnet Synchronous Motor by Antiwindup PI Controller and Comparison with Fuzzy Controller

In this paper, the driver with antiwindup and fuzzy high-performance and robust PI controller has been suggested for Permanent Magnet Synchronous Motor (PMSM). This controller is suggested for the design of the robust driver for three phase PMSM and the cost reduction of its control system. It’s useful for the industrial application and automation and ultimately speed control and the improvemen...

متن کامل

Speed Control of Permanent Magnet Synchronous Motor by Antiwindup PI Controller and Comparison with Fuzzy Controller

In this paper, the driver with antiwindup and fuzzy high-performance and robust PI controller has been suggested for Permanent Magnet Synchronous Motor (PMSM). This controller is suggested for the design of the robust driver for three phase PMSM and the cost reduction of its control system. It’s useful for the industrial application and automation and ultimately speed control and the improvemen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • IJACI

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2011