A simple iterative reduction method for optimization of quantitative magnetization transfer imaging
نویسندگان
چکیده
Introduction: Quantitative magnetization transfer imaging (QMTI) [1] yields the parameters – F, kf, R1f, T2f, and T2r – of the two-pool model for magnetization transfer (MT). Data are usually acquired using spoiled gradient-echo sequences with shaped off-resonance saturation pulses. The amplitude (or flip angle, α) and central frequency (Δ) of these saturation pulses are set according to the needs of the experiment, traditionally to cover the Z-spectrum uniformly [1,2]. Naturally, QMTI can benefit from optimized selection of the MT weightings. A previous study [3] used global Cramer-Rao Lower-Bound (CRLB) optimization of α-Δ pairs to yield sets of 10 and 15 MT weightings for brain white matter (WM) imaging, for the constant-wave-power-equivalent model of QMTI. We present a simple method for the selection of optimal MT weightings, by iterative reduction of the MT sampling from a discrete space. The optimal number of MT weightings is also investigated. Methods: The “reduction” method begins with a broad N-point sampling, X, of the Z-spectrum, and iteratively reduces the sampling by one point at a time, using an A-optimality criterion, to produce an optimized sampling. At each iteration, all sub-samplings Xj (j = 1...n), with n-1 points, of the current n-point sampling X are considered: the total estimate variance σn-1,j is computed for all Xj, using numerical propagation of error through the signal equation [4]. The Xj that results in the smallest increase in σn-1,j relative to σn (from X) is retained, thereby eliminating the α-Δ pair which provides the least information. The computation is repeated until the desired number of MT weightings is reached. In this study, the optimized sampling was derived based on typical MT model parameters for WM at 1.5 T [1] (F = 0.16, kf = 4 s, R1f = 1.7 s, T2f = 35 ms and T2r = 12 μs), from N = 320 MT weightings (2 TRs × 5 α × 32 Δ), for the rectangular-pulse model [1]. QMTI data were acquired on a 1.5 T scanner (Siemens, Erlangen, Germany) in a single female subject, using uniform and optimized 10-point samplings. The impact of sampling on reproducibility was retrospectively evaluated in 5 healthy adults (3M/2F, age 26-38) scanned four times each, with subsets of uniform 60-point data.
منابع مشابه
A Novel Classification Method using Effective Neural Network and Quantitative Magnetization Transfer Imaging of Brain White Matter in Relapsing Remitting Multiple Sclerosis
Background: Quantitative Magnetization Transfer Imaging (QMTI) is often used to quantify the myelin content in multiple sclerosis (MS) lesions and normal appearing brain tissues. Also, automated classifiers such as artificial neural networks (ANNs) can significantly improve the identification and classification processes of MS clinical datasets.Objective: We classified patients with relapsing-r...
متن کاملThe Assessment of Structural Changes in MS Plaques and Normal Appearing White Matter Using Quantitative Magnetization Transfer Imaging (MTI)
Introduction: Multiple sclerosis (MS) is a demyelinating disease of the central nervous system (CNS), affecting mostly young people at a mean age of 30 years. Magnetic resonance imaging (MRI) is one of the most specific and sensitive methods in diagnosing and detecting the evolution of multiple sclerosis disease. But it does not have the ability to differentiate between distinct histopathologic...
متن کاملPathological Assessment of Brain White Matter in Relapsing-Remitting MS Patients using Quantitative Magnetization Transfer Imaging
Introduction: Multiple sclerosis (MS) is characterized by lesions in the white matter (WM) of the central nervous system. Magnetic resonance imaging is the most specific and sensitive method for diagnosis of multiple sclerosis. However, the ability of conventional MRI to show histopathologic heterogeneity of MS lesions is insufficient. Quantitative magnetization transfer imaging (qMTI) is a rel...
متن کاملSimultaneous Echo Refocused Magnetization Transfer Imaging
Purpose: To increase the efficiency of densely encoded magnetization transfer imaging of the brain, we time-multiplex multiple slices within the same readout using simultaneous echo refocusing FLASH imaging with magnetization transfer (MT) preparation (MT-SER-FLASH). Materials and Methods: Inefficiency in total scan time results from the number of frequency samples needed for sufficient quality...
متن کاملQuantitative SPECT and planar 32P bremsstrahlung imaging for dosimetry purpose –An experimental phantom study
Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...
متن کامل