Global emissions of refrigerants HCFC-22 and HFC-134a: unforeseen seasonal contributions.
نویسندگان
چکیده
HCFC-22 (CHClF2) and HFC-134a (CH2FCF3) are two major gases currently used worldwide in domestic and commercial refrigeration and air conditioning. HCFC-22 contributes to stratospheric ozone depletion, and both species are potent greenhouse gases. In this work, we study in situ observations of HCFC-22 and HFC-134a taken from research aircraft over the Pacific Ocean in a 3-y span [HIaper-Pole-to-Pole Observations (HIPPO) 2009-2011] and combine these data with long-term ground observations from global surface sites [National Oceanic and Atmospheric Administration (NOAA) and Advanced Global Atmospheric Gases Experiment (AGAGE) networks]. We find the global annual emissions of HCFC-22 and HFC-134a have increased substantially over the past two decades. Emissions of HFC-134a are consistently higher compared with the United Nations Framework Convention on Climate Change (UNFCCC) inventory since 2000, by 60% more in recent years (2009-2012). Apart from these decadal emission constraints, we also quantify recent seasonal emission patterns showing that summertime emissions of HCFC-22 and HFC-134a are two to three times higher than wintertime emissions. This unforeseen large seasonal variation indicates that unaccounted mechanisms controlling refrigerant gas emissions are missing in the existing inventory estimates. Possible mechanisms enhancing refrigerant losses in summer are (i) higher vapor pressure in the sealed compartment of the system at summer high temperatures and (ii) more frequent use and service of refrigerators and air conditioners in summer months. Our results suggest that engineering (e.g., better temperature/vibration-resistant system sealing and new system design of more compact/efficient components) and regulatory (e.g., reinforcing system service regulations) steps to improve containment of these gases from working devices could effectively reduce their release to the atmosphere.
منابع مشابه
Theoretical Analysis of Hydrocarbon Refrigerant Mixtures as a Replacement for HCFC -22 for Residential Uses
This paper investigates the feasibility of hydrocarbon refrigerant mixtures as a replacement for HCFC-22 in residential air-conditioning and heat pump systems. The COP and the seasonal performance factor (SPF) were calculated using a UA-model for single component refrigerants and refrigerant mixtures. Simulations were run for pure propane and the mixtures of propane/i-pentane, propane/n-butane,...
متن کاملSolubility, Viscosity and Density of Refrigerant/Lubricant Mixtures
Solubility (vapor pressure) , viscosity and density have been experimentally determined for thirty-five potential refrigeration working fluids. Properties for low refrigerant concentration mixtures (0, 10, 20 and 30 weight percent refrigerant) were determined over the temperature range 0 to IOO•C (32 to 212"F) or to the critical temperature of the refrigerant, and pressure range 0 to 3,500 kPa ...
متن کاملAn analytical inversion method for determining regional and global emissions of greenhouse gases: Sensitivity studies and application to halocarbons
A new analytical inversion method has been developed to determine the regional and global emissions of long-lived atmospheric trace gases. It exploits in situ measurement data from three global networks and builds on backward simulations with a Lagrangian particle dispersion model. The emission information is extracted from the observed concentration increases over a baseline that is itself obj...
متن کاملEmission estimates of HCFCs and HFCs in California from the 2010 CalNex study
[1] The CalNex 2010 (California Research at the Nexus of Air Quality and Climate Change) study was designed to evaluate the chemical composition of air masses over key source regions in California. During May to June 2010, air samples were collected on board a National Oceanic and Atmospheric Administration (NOAA) WP-3D aircraft over the South Coast Air Basin of California (SoCAB) and the Centr...
متن کاملHeat transfer and fluid flow in spray evaporators with application to reducing refrigerant inventory
As the phase-out of chlorofluorocarbons (CFC's) approaches, there is a current need for the development of new vapor compression chillers which can operate with non-CFC refrigerants while still maintaining high operating efficiencies. Redesign of the traditional flooded evaporator used in refrigeration chillers so as to incorporate a spray evaporation capability offers both a potential for incr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Proceedings of the National Academy of Sciences of the United States of America
دوره 111 49 شماره
صفحات -
تاریخ انتشار 2014