Improved procedure for lecithin/sphingomyelin ratio in amniotic fluid reduces false predictions of lung immaturity.
نویسندگان
چکیده
Many laboratories have found that their procedure for determining lecithin/sphingomyelin (L/S)ratios gives an unacceptably high proportion of false predictions of fetal lung immaturity. We investigated each step in the procedure, in an attempt to improve the clinical performance of the test and to make the method more amenable to standardization between laboratories. L/S ratios were determined by the new procedure in amniotic fluid from 147 pregnancies, collected within two days of delivery of the infant. Four cases had an L/S ratio less than 2; all developed hyaline membrane disease. No other cases of hyaline membrane disease were encountered in this study. For 106 of these pregnancies, the L/S ratio was also determined by the procedure previously in use. This predicted lung immaturity for 16 infants, only four of whom developed hyaline membrane disease. All 12 cases incorrectly predicted as immature by the old procedure were correctly classified by the new procedure.
منابع مشابه
Improved thin-layer chromatography of disaturated phosphatidylcholine in amniotic fluid.
We describe an indirect test of fetal lung maturity: the quantitation of disaturated phosphatidylcholine in amniotic fluid. The lipids in samples of amniotic fluid from 172 patients were reacted with osmium tetroxide, and disaturated phosphatidylcholine was then isolated by thin-layer chromatography. Interfering substances were retained by a pre-adsorbent layer. The charred disaturated phosphat...
متن کاملMicroviscosity of amniotic fluid phospholipids, and its importance in determining fetal lung maturity.
Fluorescence polarization measurements of microviscosity (apparent viscosity within the hydrophobic center of lipid bilayers) of amniotic fluid correlate well with lecithin/sphingomyelin ratios determined by thin-layer chromatography. In addition to lecithin, phosphatidylglycerol and phosphatidylinositol are important for determining fetal lung maturity, but the lecithin/sphingomyelin ratio giv...
متن کاملLamellar body phospholipid content of amniotic fluid and L/S ratio compared in assessing fetal lung maturity.
A micro-method has been devised for isolating a lung-derived membranous fraction from human amniotic fluid. The phospholipid content of this fraction, known as lamellar body phospholipid, provides an indication of fetal lung maturity (Ann. Clin. Biochem 16: 191, 1979). This method has now been applied to 479 samples of amniotic fluid from 330 pregnancies. The lecithin/sphingomyelin ratio has al...
متن کاملAssessment of fetal lung maturity by colorimetric phospholipid determination without digestion.
A previously described method for the determination of phospholipid concentration in amniotic fluid without digestion has been modified to make it more suitable for use in a routine laboratory. Results compare well with those by the original procedure. Results from nearly 70 amniotic fluids, collected at delivery, were compared with lecithin/sphingomyelin (L/S) ratios determined on the same flu...
متن کاملMeasurement of amniotic fluid surfactant.
Measurement of the production of surfactant is the most direct means of prenatally assessing fetal pulmonary maturity. We review assays which have evolved for measuring surfactant, classifying them into two general categories: biochemical quantitation and biophysical measurements. Biochemical quantitation assays include the amniotic fluid lecithin/sphingomyelin ratio and quantitation of lecithi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 28 2 شماره
صفحات -
تاریخ انتشار 1982