Comparison of dynamic contrast-enhanced gradient-echo and spin-echo sequences in MR of head and neck neoplasms.

نویسندگان

  • E J Escott
  • V M Rao
  • W D Ko
  • J E Guitierrez
چکیده

PURPOSE To investigate the utility of dynamic contrast-enhanced gradient-echo MR imaging of head and neck lesions and to compare this technique with the commonly used spin-echo contrast-enhanced fat-saturation technique. METHODS Twenty-two patients with a total of 23 head and neck neoplasms underwent dynamic gradient-echo and spin-echo MR imaging studies. The spin-echo and dynamic gradient-echo images were compared in each case by consensus of three observers for differences in tumor conspicuity and delineation of margins, particularly with regard to invasion of adjacent structures. When possible, pathologic and/or surgical confirmation of tumor extent was obtained. Relative contrast was also calculated to determine objectively the degree of tumor enhancement with respect to background mucosa. RESULTS The dynamic gradient-echo images showed better or equal delineation of the tumor margins by subjective observation in all but two cases. Temporally different enhancement patterns were noted for lesions, background mucosa, and adjacent reaction and edema. The dynamic gradient-echo technique provided better relative contrast than the spin-echo technique in 17 (77%) of 22 lesions. CONCLUSION Dynamic gradient-echo MR imaging is superior to conventional contrast-enhanced spin-echo imaging in delineating the margins and extent of tumor. This technique provided observers with added confidence in their interpretations and suffered from fewer technical limitations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of blood-brain-barrier permeability dysregulation and inflammatory activity in MS lesions by dynamic-contrast enhanced MR imaging

Objective: Measurement of blood-brain permeability dysfunction in active and chronic MS lesions with T1-weighted dynamic contrast-enhanced MRI to show variation in inflammatory activity Background: blood-brain-barrier perfusion characterization impaired in MS as some studies have shown recently buta comparison between perfusion parameters in contrast-enhanced and non-enhanced lesions not have ...

متن کامل

Head and neck paragangliomas: improved tumor detection using contrast-enhanced 3D time-of-flight MR angiography as compared with fat-suppressed MR imaging techniques.

BACKGROUND AND PURPOSE MR imaging techniques have proved their efficacy in imaging the head and neck region. In this study, we compared T1-weighted, dual T2-weighted, and fat-suppressed MR imaging and unenhanced and contrast-enhanced 3D time-of-flight MR angiography sequences for detection of head and neck paragangliomas. METHODS Thirty-one patients with 70 paragangliomas were examined. Four ...

متن کامل

MR of the head and neck: comparison of fast spin-echo and conventional spin-echo sequences.

PURPOSE To compare conspicuousness of head and neck lesions on fast spin-echo sequences and conventional spin-echo sequences. METHODS Forty consecutive patients with 61 head and neck lesions were evaluated. Lesion conspicuousness was qualitatively compared on conventional spin-echo and fast spin-echo sequences, using both spin-density and T2-weighted images. Thirty-six lesions had surgical or...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Comparison of Three-Dimensional Double-Echo Steady-State Sequence with Routine Two-Dimensional Sequence in the Depiction of Knee Cartilage

Introduction: There are some routine two-dimensional sequences, including short tau inversion recovery (STIR), T2-weighted fast-spin echo (T2W-FSE), and proton-density fast spin-echo for diagnosing osteoarthritis and lesions of the knee cartilage. However, these sequences have some disadvantages, such as long scan time, inadequate spatial resolution, and suboptimal tis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 18 8  شماره 

صفحات  -

تاریخ انتشار 1997