Penumbra Pattern Assessment in Acute Stroke Patients: Comparison of Quantitative and Non-Quantitative Methods in Whole Brain CT Perfusion
نویسندگان
چکیده
BACKGROUND AND PURPOSE While penumbra assessment has become an important part of the clinical decision making for acute stroke patients, there is a lack of studies measuring the reliability and reproducibility of defined assessment techniques in the clinical setting. Our aim was to determine reliability and reproducibility of different types of three-dimensional penumbra assessment methods in stroke patients who underwent whole brain CT perfusion imaging (WB-CTP). MATERIALS AND METHODS We included 29 patients with a confirmed MCA infarction who underwent initial WB-CTP with a scan coverage of 100 mm in the z-axis. Two blinded and experienced readers assessed the flow-volume-mismatch twice and in two quantitative ways: Performing a volumetric mismatch analysis using OsiriX imaging software (MM(VOL)) and visual estimation of mismatch (MM(EST)). Complementarily, the semiquantitative Alberta Stroke Programme Early CT Score for CT perfusion was used to define mismatch (MM(ASPECTS)). A favorable penumbral pattern was defined by a mismatch of ≥ 30% in combination with a cerebral blood flow deficit of ≤ 90 ml and an MM(ASPECTS) score of ≥ 1, respectively. Inter- and intrareader agreement was determined by Kappa-values and ICCs. RESULTS Overall, MM(VOL) showed considerably higher inter-/intrareader agreement (ICCs: 0.751/0.843) compared to MM(EST) (0.292/0.749). In the subgroup of large (≥ 50 mL) perfusion deficits, inter- and intrareader agreement of MM(VOL) was excellent (ICCs: 0.961/0.942), while MM(EST )interreader agreement was poor (0.415) and intrareader agreement was good (0.919). With respect to penumbra classification, MM(VOL) showed the highest agreement (interreader agreement: 25 agreements/4 non-agreements/κ: 0.595; intrareader agreement 27/2/0.833), followed by MM(EST) (22/7/0.471; 23/6/0.577), and MM(ASPECTS) (18/11/0.133; 21/8/0.340). CONCLUSION The evaluated approach of volumetric mismatch assessment is superior to pure visual and ASPECTS penumbra pattern assessment in WB-CTP and helps to precisely judge the extent of 3-dimensional mismatch in acute stroke patients.
منابع مشابه
Perfusion computed tomography relative threshold values in definition of acute stroke lesions
BACKGROUND Perfusion computed tomography (CT) is a relatively new technique that allows fast evaluation of cerebral hemodynamics by providing perfusion maps and gives confirmation of perfusion deficits in ischemic areas. Some controversies exist regarding accuracy of quantitative detection of tissue viability: penumbra (tissue at risk) or core (necrosis). PURPOSE To define brain tissue viabil...
متن کاملComputed tomography perfusion measurements for definition of lesions in early acute stroke
Background: Perfusion computed tomography (CT) is an evolving technique in the diagnosis of acute stroke. After complex deconvolution algorithms, perfusion color maps-cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT)— are produced, they give visual confirmation of perfusion deficit in ischemic area, but some discrepancies exist regarding this technique in relia...
متن کاملEvaluation of role of brain SPECT in diagnosis of post stroke dementia [Persian]
Post stroke dementia is one of the most common complications of stroke that is preventable and relatively treatable too. The purpose of the study is comparison between the positive findings in brain CT scan and brain perfusion SPECT. 15 patients who were complicated by dementia after cerebrovascular accident and also 5 patients as a control group enrolled in this study. Brain CT scan and ...
متن کاملComparison of admission perfusion computed tomography and qualitative diffusion- and perfusion-weighted magnetic resonance imaging in acute stroke patients.
BACKGROUND AND PURPOSE Besides classic criteria, cerebral perfusion imaging could improve patient selection for thrombolytic therapy. The purpose of this study was to compare quantitative perfusion CT imaging and qualitative diffusion- and perfusion-weighted MRI (DWI and PWI) in acute stroke patients at the time of their emergency evaluation. METHODS Thirteen acute stroke patients underwent p...
متن کاملQuantitative assessment of core/penumbra mismatch in acute stroke: CT and MR perfusion imaging are strongly correlated when sufficient brain volume is imaged.
BACKGROUND AND PURPOSE Our purpose was to determine (1) the correlation between quantitative CT and MR measurements of infarct core, penumbra, and mismatch; and (2) whether the difference between these measurements would alter patient selection for stroke clinical trials. METHODS We studied 45 patients with acute middle cerebral artery stroke imaged a mean of 3.8 hours after onset (range, 0.4...
متن کامل