Comparison of the sensitivity and specificity of six immunoassays for the detection of amphetamines in urine.

نویسندگان

  • Alain G Verstraete
  • Fien V Heyden
چکیده

We analyzed 225 urine samples with FPIA (Abbott Amphetamine/Methamphetamine II on ADx and AxSYM), EMIT (Emit II Plus Monoclonal Amphetamine/Metamphetamine assay and EMIT II Plus Amphetamines assay, EMIT N), and KIMS (standard protocol and MDMA protocol, KIMS and KIMS X, respectively) immunoassays and compared their sensitivity and specificity. All assays were calibrated and used semi-quantitatively. All samples that screened positive by any amphetamine screening method and 15% of the negative samples were confirmed by liquid chromatography-tandem mass spectrometry (LC-MS-MS). A sample was considered positive for amphetamines if amphetamine, methamphetamine, methylenedioxymethamphetamine, methylenedio-xyethylamphetamine, or methylenedioxyamphetamine was present at 250 ng/mL. Ninety (40%) of the samples were positive by LC-MS-MS. The areas under the receiver operating characteristic curve varied between 0.972 (KIMS X) and 1.000 (ADx). The optimal cut-off concentrations varied between 271 ng/mL (EMIT N) and 723 ng/mL (AxSYM). The sensitivity was 100% for ADx and between 93 and 95% for the other assays. The specificity varied between 88% (KIMS) and 100% (EMIT N). Use of a 500 ng/mL screening cut-off would have resulted in identical or very similar results for ADx and KIMS X and large increases in the false positives for AxSYM and EMIT and the false negatives for EMIT N and KIMS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of ELISA and TLC Methods for the Morphine Detection in Urine of Drug Abusers

Background: The current study was conducted to compare ELISA with thin layer chromatography (TLC) methods for diagnosis of morphine in the urine. Methods: Positive urine samples for morphine confirmed by immunochromatographic strips were collected from the Imam Reza Toxicology Laboratory, Mashhad University of Medical Sciences, Mashhad, Iran in 2012 for the current study. Then, the collated ...

متن کامل

Evaluation of Sensitivity and Specificity of Urine Survivin As A New Molecular Marker in Diagnosis of Bladder Tumors

Bladder cancer is one of the most common forms of cancers in the world. The current gold standards for itsdiagnosis are cystoscopy and urine cytology. Cystoscopy, a naked eye assessment of the bladder, is invasive, uncomfortable and costly with a great deal of personal variability in its results; while urine cytology has high specificity but low sensitivity, particularly for low-grade les...

متن کامل

ارزیابی روش‌های الکتروایمونواسی و 100Clinitek- برای تشخیص میکروآلبومینوری

Evaluation of Electroimmunoassay and Clinitek-100 for Detection of Microalbuminuria B.A. Jalali Khanabadi PhD , H. Mozaffari Khosravi PhD Received: 12/10/05 Sent for Revision: 04/03/06 Received Revised Manuscript: 20/01/07 Accepted: 25/01/07 Background and Objective: Detection of microalbuminuria is an important laboratory test for evaluation of diabetic complications. A reliable me...

متن کامل

A Capture ELISA for the Diagnosis of Visceral Leishmaniasis Using a Monoclonal Antibody against a Leishmanial

capture ELISA system was developed for diagnosis of visceral leishmaniasis (VL) using a monoclonal antibody raised against an antigen previously detected in the urine of VL patients. Urine samples from confirmed VL cases from Yemen, Nepal, Spain, Sudan and Brazil were tested in the capture ELISA in comparison with urine samples from endemic and non-endemic areas along with urine samples from pa...

متن کامل

Evaluation of 8-hour and 12-hour urine collection for detection of proteinuria in hypertensive women, Shariati hospital, 2004 - 2005

Introduction: Hypertensive disorders are common during pregnancy. Combination of hypertension and proteinuria markedly increase prenatal morbidity and mortality. The gold standard method for proteinuria assessment is 24-hour urine collection. This survey is designed to determine the correlation between protein content of 8-hour and 24-hour urine collections. Methods: This cross-sectional study...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of analytical toxicology

دوره 29 5  شماره 

صفحات  -

تاریخ انتشار 2005