Effectiveness of inhaler types for real-world asthma management: retrospective observational study using the GPRD
نویسندگان
چکیده
PURPOSE Results of randomized controlled trials may not predict effectiveness of inhaled corticosteroids (ICS) in real-world clinical practice, where inhaler technique and device characteristics can influence effectiveness. We compared asthma outcomes for ICS delivered via three different inhaler devices: pressurized metered-dose inhaler (pMDI), breath-actuated MDI (BAI), and dry powder inhaler (DPI). PATIENTS AND METHODS This retrospective database study evaluated 1-year outcomes for primary care patients with asthma aged 5-60 years prescribed their first ICS (initiation population) by pMDI (n = 39,746), BAI (n = 9809), or DPI (n = 6792), or their first ICS dose increase (step-up population) by pMDI (n = 6245), BAI (n = 1388), or DPI (n = 1536). Co-primary outcome measures were composite proxy measures of asthma control (no hospital attendance for asthma, oral corticosteroids, or antibiotics for lower respiratory infection) and severe exacerbations (unscheduled hospital admission, emergency room attendance, or oral corticosteroids). Outcomes were adjusted for potential confounding factors identified during a baseline year. RESULTS In the initiation population, adjusted odds ratios (95% confidence intervals [CI]) for asthma control, as compared with pMDIs, were significantly better for BAIs (1.08 [1.02-1.14]) and DPIs (1.13 [1.06-1.21]), while adjusted exacerbation rate ratios (95% CI) were 1.00 (0.93-1.08) and 0.88 (0.81-0.95), respectively. In the step-up population, adjusted odds of asthma control were 1.21 (1.05-1.39) for BAIs and 1.13 (0.99-1.29) for DPIs; adjusted exacerbation rate ratios were 0.83 (0.71-0.98) for BAIs and 0.85 (0.74-0.98) for DPIs, compared with pMDIs. CONCLUSION Inhaler device selection may have a bearing on clinical outcomes. Differences in real-world effectiveness among these devices require closer evaluation in well-designed prospective trials.
منابع مشابه
Effectiveness of Same Versus Mixed Asthma Inhaler Devices: A Retrospective Observational Study in Primary Care
PURPOSE Correct use of inhaler devices is fundamental to effective asthma management but represents an important challenge for patients. The correct inhalation manoeuvre differs markedly for different inhaler types. The objective of this study was to compare outcomes for patients prescribed the same inhaler device versus mixed device types for asthma controller and reliever therapy. METHODS T...
متن کاملCost-effectiveness analysis of corticosteroid inhaler devices in primary care asthma management: A real world observational study
PURPOSE To evaluate and compare real world cost-effectiveness of inhaled corticosteroids (ICS) administered by metered dose inhaler (MDI), breath-actuated MDI (BAI), or dry powder inhaler (DPI) in asthma. PATIENTS AND METHODS This retrospective database study analyzed the direct health care costs and proportion of patients (aged 5-60 years) achieving asthma control over 1 year in two populati...
متن کاملPhysicians’ attitudes towards combination therapy with inhaled corticosteroids and long-acting β2-agonists: an observational study in UK specialist care
PURPOSE Recent real-world studies have demonstrated that asthma control remains suboptimal in many patients. The aim of this study was to evaluate physicians' perceptions of the effectiveness of combination therapy with an inhaled corticosteroid (ICS) and a long-acting β2-agonist (LABA) in routine clinical practice. METHODS In November 2009, UK respiratory specialists were invited by medeConn...
متن کاملAre outcomes the same with all dry powder inhalers?
Most clinicians and patients would intuitively say that the inhaler device used influences the outcome achieved in asthma. However, it is important to have objective evidence to support or refute this view. Systematic reviews have suggested that there is no difference in clinical effectiveness between dry powder inhalers and metered-dose inhalers. However, the studies included in the review wer...
متن کاملThe Salford Lung Study protocol: a pragmatic, randomised phase III real-world effectiveness trial in asthma
BACKGROUND Novel therapies need to be evaluated in normal clinical practice to allow a true representation of the treatment effectiveness in real-world settings. METHODS/DESIGN The Salford Lung Study is a pragmatic randomised controlled trial in adult asthma, evaluating the clinical effectiveness and safety of once-daily fluticasone furoate (100 μg or 200 μg)/vilanterol 25 μg in a novel dry-p...