Comparison of transcranial electric motor and somatosensory evoked potential monitoring during cervical spine surgery.
نویسندگان
چکیده
BACKGROUND There has been little enthusiasm for somatosensory evoked potential monitoring in cervical spine surgery as a result, in part, of the increased risk of motor tract injury at this level, to which somatosensory monitoring may be insensitive. Transcranial electric motor evoked potential monitoring allows assessment of the motor tracts; therefore, we compared transcranial electric motor evoked potential and somatosensory evoked potential monitoring during cervical spine surgery to determine the temporal relationship between the changes in the potentials demonstrated by each type of monitoring and neurological sequelae and to identify patient-related and surgical factors associated with intraoperative neurophysiological changes. METHODS Somatosensory evoked potential and transcranial electric motor evoked potential data recorded for 427 patients undergoing anterior or posterior cervical spine surgery between January 1999 and March 2001 were analyzed. All patients who showed substantial (at least 60%) or complete unilateral or bilateral amplitude loss, for at least ten minutes, during the transcranial electric motor evoked potential and/or somatosensory evoked potential monitoring were identified. RESULTS Twelve of the 427 patients demonstrated substantial or complete loss of amplitude of the transcranial electric motor evoked potentials. Ten of those patients had complete reversal of the loss following prompt intraoperative intervention, whereas two awoke with a new motor deficit. Somatosensory evoked potential monitoring failed to identify any change in one of the two patients, and the change in the somatosensory evoked potentials lagged behind the change in the transcranial electric motor evoked potentials by thirty-three minutes in the other. No patient showed loss of amplitude of the somatosensory evoked potentials in the absence of changes in the transcranial electric motor evoked potentials. Transcranial electric motor evoked potential monitoring was 100% sensitive and 100% specific, whereas somatosensory evoked potential monitoring was only 25% sensitive; it was, however, 100% specific. CONCLUSIONS Transcranial electric motor evoked potential monitoring appears to be superior to conventional somatosensory evoked potential monitoring for identifying evolving motor tract injury during cervical spine surgery. Surgeons should strongly consider using this modality when operating on patients with cervical spondylotic myelopathy in general and on those with ossification of the posterior longitudinal ligament in particular.
منابع مشابه
Bilateral C5 Palsy Following a Circumferential Surgery for Cervical Spondylotic Myelopathy: Case Report and Review (In press)
Background and Importance: The development of C5 root palsy is a well-known potential complication of cervical spine surgeries for the correction of cervical spondylotic myelopathy. It typically occurs unilaterally but on extremely rare occasions it might occur as a bilateral anomaly. The value of intraoperative neurophysiologic monitoring in detection of iatrogenic acute versus delayed onset C...
متن کاملEvolving compartment syndrome detected by loss of somatosensory- and motor-evoked potential signals during cervical spine surgery.
Neurologic injury is a rare but devastating complication of spinal surgery that can result in mild sensory to severe motor deficits. Surgeons increasingly use electrophysiological spinal cord function monitoring, including somatosensory- and motor-evoked potentials, intraoperatively to provide information about spinal cord function, aid in surgical decision making, improve outcomes, and reduce ...
متن کاملTwo cases of quadriparesis following anterior cervical discectomy, with normal perioperative somatosensory evoked potentials.
Two cases illustrate an uncommon failure of perioperative somatosensory evoked potential (SEP) monitoring to detect iatrogenic lesions causing temporary quadriparesis during straightforward cervical surgery. In both cases, anterior cervical discectomy at one or two levels was undertaken with bone graft and titanium implants, and cortical SEP were monitored to alternate stimulation of the left a...
متن کاملNeurophysiological monitoring of spinal cord function during instrumented anterior cervical fusion.
BACKGROUND CONTEXT Somatosensory evoked potentials (SSEPs) monitor global spinal cord function, and the interpretation of motor loss is based on inferred rather than direct measurements. Therefore, SSEPs may not be useful for identifying motor function deficits caused by anterior spinal column injury or nerve root injury during decompression or placement of instrumentation. For these reasons, a...
متن کاملLoss of transcranial electric motor evoked potentials during pediatric spine surgery with dexmedetomidine.
Case report: Intraoperative neurophysiologic monitoring using transcranial electric motor evoked potentials (TceMEP) has been increasingly utilized to reduce the risk of spinal cord injury during corrective spine surgery. Since inhalational anesthetic agents considerably depress TceMEP amplitude in a dose dependent manner (1,2), total intravenous anesthesia (TIVA) techniques with propofol as a ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. American volume
دوره 86-A 6 شماره
صفحات -
تاریخ انتشار 2004