Development of the Ion Exchange-Gravimetric Method for Sodium in Serum as a Definitive Method
نویسندگان
چکیده
An ion exchange-gravimetric method, previously developed as a National Committee for Clinical Laboratory Standards (NCCLS) reference method for the determination of sodium in human serum, has been re-evaluated and improved. Sources of analytical error in this method have been examined more critically and the overall uncertainties decreased. Additionally, greater accuracy and repeatability have been achieved by the application of this definitive method to a sodium chloride reference material. In this method sodium in serum is ion-exchanged, selectively eluted and converted to a weighable precipitate as Na2SO4. Traces of sodium eluting before or after the main fraction, and precipitate contaminants are determined instrumentally. Co-precipitating contaminants contribute less than 0.1 % while the analyte lost to other eluted ion-exchange fractions contributes less than 0.02 % to the total precipitate mass. With improvements, the relative expanded uncertainty (k = 2) of the method, as applied to serum, is 0.3 % to 0.4 % and is less than 0.1 % when applied to a sodium chloride reference material.
منابع مشابه
Development of a new method based on chiral ligand-exchange chromatography for the enantioseparation of propranolol
A new chromatographic procedure was proposed for the separation of propranolol (PRN) enantiomers based upon enantioselective chiral ligand-exchange chromatography. The separation was carried out on a short C8 column leading to considerably short separation time. L-alanine and Cu2+ were applied as chiral selector and central bivalent complexing ion, respectively. It was found that the kind of co...
متن کاملDevelopment of a new method based on chiral ligand-exchange chromatography for the enantioseparation of propranolol
A new chromatographic procedure was proposed for the separation of propranolol (PRN) enantiomers based upon enantioselective chiral ligand-exchange chromatography. The separation was carried out on a short C8 column leading to considerably short separation time. L-alanine and Cu2+ were applied as chiral selector and central bivalent complexing ion, respectively. It was found that the kind of co...
متن کاملSynthesis of neopentyl glycol and ethylene glycol esters by fatty acids in the presence of acidic ion exchange resin catalyst
A most effective and less energy demanding method of producing fatty esters, diol esters, by esterifying fatty acids, with neopentyl and ethylenglycol alcohols in the presence of an acidic ion exchange resin catalyst(polyestyrendivinylbenzensulfated) was investigated at elevated temperature. In this process an azeotroping agent, toluene, was used to facilitate continuous removal of water by dis...
متن کاملA novel MRI contrast agent synthesized by ion exchange method
Objective: In this study, the zeolite-coated iron oxide nanoparticles were evaluated as MRI contrast agent and effect of the nanocomposite synthesis method on MRI contrast was tested. Materials and Methods: Ion exchange method was used for synthesis of iron oxide-zeolite and the as prepared nanocomposite was characterized by XRD, FESEM and TEM. The nanocomposite toxicity in the cell culture, a...
متن کاملDevelopment and Validation of an Ion Chromatography Method for Quantification of Ammonium Ions in STEALTH® Liposomes
Ammonium sulfate is one of the subsidiary components in the stealth liposome structure. The ratio of ammonium ion bound to liposome sphere to ammonium ions outside the liposome plays an important role in drug delivery formulation; accordingly, in order to quantify the ammonium ion in the liposome structure, a rapid and sensitive method was validated using a conductivity detector. Through this m...
متن کامل