X-RAY MICROBEAM DIFFRACTION COMPARISON OF MESOTEXTURES IN PLATES OF THREE ALUMINUM ALLOYS, K. Ignatiev, S.R. Stock, Z.U. Rek, pp. 56-61
نویسنده
چکیده
Samples from the center of plates of rolled aluminum alloys AA 8090 and 7055 were investigated using microbeam diffraction and polychromatic synchrotron x-ray radiation. Transmission Laue patterns from different parts of the samples were compared and analyzed for the presence of mesotexture similar to that observed previously in the center of plates of aluminum alloy AA 2090 (i.e., near single-crystal volumes of 5 to 10 or more adjacent grains with nearly identical orientation). The macrotexture and grain morphology of the AA 8090 samples were quite similar to those of samples of AA 2090; the macrotexture and grain morphology of the AA 7055 sample differed from those of AA 2090. Approximately 10% of the AA 8090 volume consisted of material with the near single-crystal mesotexture (compared to about 40% typical for AA 2090) while no near single-crystal volumes were observed in the AA 7055 material.
منابع مشابه
FATIGUE CRACKS IN ALUMINUM SAMPLES STUDIED WITH X-RAY PHASE CONTRAST IMAGING AND WITH ABSORPTION MICROTOMOGRAPHY, S.R. Stock, K. Ignatiev, G.R. Davis, J.C. Elliott, K. Fezzaa, W.-K. Lee, pp. 123-127
X-ray absorption microtomography, a high resolution variant of medical “CT”, quantifies threedimensional microstructures efficiently and noninvasively. With this imaging modality, determination of the three-dimensional spatial distribution of crack opening as a function of applied load has helped clarify important physical processes of roughness-induced fatigue crack closure. There is a real ne...
متن کاملSULFATE ATTACK OF PORTLAND CEMENT STUDIED BY X-RAY MICROTOMOGRAPHY (MICRO-CT), S.R. Stock, K. Ignatiev, A.P. Wilkinson, N. Naik, K.E. Kurtis, pp. 128-132
Attack of Portland cement by ambient sulfates presents a considerable risk to structures in some environments. In this study, x-ray microtomography, a high resolution variant of medical “CT”, noninvasively mapped the progression of damage in Portland cement resulting from exposure to an aqueous solution of Na2SO4 (sodium ion concentration of 10,000 ppm). Cement paste samples from water-to-cemen...
متن کاملThree-dimensional Mapping of Fatigue Crack Position via a Novel X-ray Phase Contrast Approach
X-ray absorption microtomography loses considerable sensitivity when it is applied to samples with high-aspect-ratio cross-sections, e.g. plates or compact tension samples. Synchrotron X-ray phase enhanced imaging is much more sensitive than absorption-based techniques to cracks with small openings, and phase imaging and stereometric techniques are developed in this paper for three-dimensional ...
متن کاملThe Effect of Nickel Increasing and Aluminum Addition on Sulfidation Resistance of Fe-Ni-Cr Alloys (TECHNICAL NOTE)
In this research the effects of; increasing the amount of nickel and adding aluminum to create and prolong sulfidation resistance of Fe-Ni-Cr alloys have been investigated. Sulfidation tests were carried out at 1100°C in S/O bearing atmosphere. Prior to the tests, the specimens were annealed in argon at 1250°C for 8 hrs. Weight changes were measured and corroded deposits were analyzed byscannin...
متن کاملEFFECT OF ANNEALING ON MICROSTRUCTURE AND CORROSION PERFORMANCE OF ADB AND ALB ALLOYS
Microstructure and corrosion performance of admiralty brass (ADB) and aluminum brass (ALB) alloys after passing different annealing heat treatments were investigated using optical and scanning electron microscope, energy dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), DC polarization measurements and electrochemical impedance spectroscopy (EIS). The results showed that heat tre...
متن کامل