Corneal biomechanical changes in diabetes mellitus and their influence on intraocular pressure measurements.
نویسندگان
چکیده
PURPOSE To investigate possible corneal biomechanical changes in patients with diabetes mellitus and understand the influence of such changes on intraocular pressure measurements. METHODS The study group was composed of 120 eyes from 61 healthy control subjects and 81 eyes from 43 diabetic subjects. IOP was measured first with an ocular response analyzer (ORA) and subsequently with a Goldmann applanation tonometer (GAT). Central corneal thickness (CCT) was measured with an ultrasonic pachymeter attached to the ORA. Axial length (AL), anterior chamber depth (ACD), and keratometry readings were acquired with partial coherence laser interferometry during the same visit before all IOP and CCT determinations were made. RESULTS Corneal hysteresis (CH) was found to be significantly lower in diabetic patients when compared with healthy control subjects (9.51 +/- 1.82 mm Hg vs. 10.41 +/- 1.66 mm Hg, P < 0.0001). There was no significant difference in terms of corneal resistance factor (CRF; P = 0.8). Mean CCT, GAT IOP, Goldmann-correlated IOP (IOPg), and corneal-compensated IOP (IOPcc) were significantly higher in diabetic patients than in healthy control subjects (P = 0.01 for CCT, P < 0.0001 for GAT IOP, IOPg, and IOPcc). CONCLUSIONS Diabetes affects corneal biomechanics and results in lower CH values than those in healthy control subjects, which may cause clinically relevant high IOP measurements independent of CCT.
منابع مشابه
Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea
Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...
متن کاملEffect of diabetes mellitus on biomechanical parameters of the cornea.
PURPOSE To compare parameters of biomechanical response of the human cornea measured as corneal hysteresis (CH) and corneal resistance factor (CRF) in patients with diabetes mellitus and healthy control subjects. SETTING Department of Ophthalmology, Assaf Harofeh Medical Center, Zerifin, Israel. METHODS In the right eye of each participant, the CH, CRF, Goldmann-correlated intraocular press...
متن کاملEvaluation of the relationship between corneal biomechanic and HbA1C levels in type 2 diabetes patients
PURPOSE To evaluate the corneal biomechanical properties due to the glycosylated hemoglobin (HbA1C) levels using the ocular response analyzer (ORA) in the patients with type 2 diabetes mellitus (DM). METHODS ORA values were obtained from 156 eyes of subjects with type 2 DM and 74 eyes of healthy control subjects with similar age and sex. Subjects were divided into three groups: Group 1, healt...
متن کاملEffect of Ocular Biomechanics on Intraocular Pressure Measurement in Mucopolysaccharidosis I-S (Scheie’s Syndrome)
Purpose: To study the effect of biomechanical properties of the cornea on the intraocular pressure in eyes affected with Mucopolysaccharidosis type I-S (Scheie's syndrome). Methods: Four eyes of two patients in their mid-fifties diagnosed with Scheie's syndrome were investigated for corneal biomechanical properties. The corneal biomechanical profile was assessed by the use of Ocular response an...
متن کاملEffects of eye rubbing and breath holding on corneal biomechanical properties and intraocular pressure.
PURPOSE To determine whether corneal biomechanical properties and intraocular pressure (IOP) are affected by eye rubbing and breath holding. METHODS Corneal hysteresis, corneal resistance factor, corneal compensated IOP (IOPcc), and Goldmann equivalent IOP (IOPg) were measured on both eyes of 40 subjects. Measurements were taken at baseline before eye rubbing (ER(0)) and before breath holding...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 50 10 شماره
صفحات -
تاریخ انتشار 2009