Longitudinal straightening effect of stents is an additional predictor for major adverse cardiac events. Austrian Wiktor Stent Study Group and European Paragon Stent Investigators.

نویسندگان

  • M Gyöngyösi
  • P Yang
  • A Khorsand
  • D Glogar
چکیده

OBJECTIVES The aim of this study was to perform an investigation of the effects of the longitudinal straightening of coronary arteries by stents and the possible association with major adverse cardiac events (MACE) (primary end point) and angiographic restenosis (secondary end point). BACKGROUND Stent deployment straightens a tortuous artery, and any consequent arterial longitudinal stretch may contribute to MACE and stent restenosis severity. METHODS Clinical, qualitative and quantitative angiographic data on 404 patients with single stent implantation were subjected to multivariate nominal logistic regression analysis for the prediction of MACE. The predictive accuracy, sensitivity and specificity values and cut-off points of the continuous variables were determined via receiver operating characteristics curves. The longitudinal straightening effect of stents was characterized through the changes in vessel angle (defined by the tangents to the proximal and distal parts of the stenoses/stents). RESULTS Follow-up angiography on 354 patients revealed 73 cases of stent restenosis (> or =50% diameter stenosis). Coronary bypass surgery was performed in 4 patients and repeated percutaneous transluminal coronary angioplasty in 56 patients; acute myocardial infarction (AMI) occurred in 2 patients, and 4 patients died during the follow-up. The overall incidence of MACE (death, AMI and revascularization) was 16.3% (66 patients). The best predictive accuracies and sensitivities/specificities of factors indicative of MACE were found for the minimal lumen diameter (MLD) at follow-up (predictive accuracy: 0.9305, sensitivity/specificity: 86.6%), the post-stent MLD (0.773, 77.2%), the percent diameter stenosis (%DS) at follow-up (0.9432, 87.1%), the prestent vessel angulation (0.6797, 68.2%) and the poststent changes in vessel angulation (0.6279, 62.2%). Multivariate nominal logistic regression analysis demonstrated that a poststent MLD < or =2.63 mm (p = 0.0017, odds ratio [OR] = 17.961, 95% confidence interval [CI] = 17.45-20.428), an MLD at follow-up < or =1.7 mm (p = 0.0059, OR = 11.880, 95% CI = 11.490-14.093), a %DS at follow-up > or =42.2% (p = 0.0000, OR = 49.553, 95% CI = 48.024-53.507), a prestent vessel angulation > or =33.5 degrees (p = 0.0477, OR = 5.404, 95% CI = 5.382-7.142) and poststent changes in vessel angulation > or =9.1 degrees (p = 0.0026, OR = 19.161, 95% CI = 18.562-21.750) were significant predictors for MACE. Multiple linear regression revealed that the poststent MLD (multivariate p = 0.0001), the MLD at follow-up (p = 0.0000), the prestent vessel angulation (p = 0.0431) and the changes in vessel angulation after stent implantation (p = 0.0316) were significant independent variables predicting angiographic stent restenosis severity. CONCLUSIONS The longitudinal straightening effect of coronary artery stents contributes significantly to the occurrence of MACE and angiographic restenosis, and this finding may have an impact on future stent design.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Stent Expansion by Stent Balloon Multiple Inflation at Nominal Pressure in Resistant Lesions: A New Technique

Introduction: This study aimed to evaluate the effects of four-time inflation of the stent balloon at nominal pressure on optimal stent expansion in resistant lesions. Materials and Methods: This interventional study was conducted on 39 patients with coronary artery lesions, in whom Zotarolimus-eluting stents (N=20), Paclitaxel-eluting stents (N=11) and other stents (N=8) were deployed four tim...

متن کامل

Heparin-coated Wiktor stents in human coronary arteries (MENTOR trial). MENTOR Trial Investigators.

The purpose of this study was to determine the feasibility, safety, and efficacy of elective stenting with heparin-coated Wiktor stents in patients with coronary artery disease. In experimental studies, heparin coating has been shown to prevent subacute thrombosis and restenosis. Recently, a new method of heparin coating was developed, resulting in a more stable and predictable heparin layer on...

متن کامل

نتایج بالینی پس از آنژیوپلاستی عروق کرونر، بروز حوادث بزرگ قلبی-عروقی و عوارض انواع استنت

Background: Cardiovascular diseases alone have become the leading cause of death worldwide. One of the treatment methods cardiovascular disease is angioplasty. This study aimed to investigate the clinical results after coronary artery angioplasty, based on the incidence of major cardiovascular events with emphasis on stent types. Methods: In this retrospective cross-sectional study, the preval...

متن کامل

Adverse clinical events in patients treated with sirolimus-eluting stents: the impact of Type D personality.

BACKGROUND Little is known about the impact of psychological risk factors on cardiac prognosis in the drug-eluting stent era. We examined whether the distressed personality (Type D) moderates the effect of percutaneous coronary intervention with sirolimus-eluting stent implantation on adverse clinical events at 2-year follow-up. Type D is an emerging risk factor in patients with cardiovascular ...

متن کامل

History of allergy is a predictor of adverse events in unstable angina treated with coronary angioplasty.

BACKGROUND The aim was to investigate prognostic relevance of history of allergy in subjects with unstable angina treated with coronary angioplasty. METHODS Fifty-seven consecutive patients with unstable angina who underwent coronary angioplasty were enrolled in the study and were divided into two groups: those with a history of allergy (Group A, N = 15); and controls (Group C, N =42). Major ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 35 6  شماره 

صفحات  -

تاریخ انتشار 2000