PURPOSE To assess the value of an added gradient echo in the same pulse sequence with a T1-weighted spin echo for determining the presence of an abnormal fluid collection in the temporomandibular joint with no additional imaging time. MATERIALS AND METHODS Using a standard T1-weighted sequence used in cine temporomandibular joint imaging, a readout gradient reversal was added and the resulting gradient echo collected. This image was compared with standard T1- and T2-weighted sequences, a short inversion recovery imaging sequence, and a small flip angle fast low-angle shot gradient-echo sequence. RESULTS The T1-weighted spin echo preceding the added gradient echo is not affected by the gradient reversal, but the additional gradient echo adds T2* contrast information that displays fluid as bright as and compares favorably with other fluid detection sequences. CONCLUSION The added gradient-echo technique adds sensitivity for the detection of an abnormal increase in fluid in the temporomandibular joint without adding to the overall imaging time of a routine T1-weighted sequence.
منابع مشابه
Non-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)
Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different and weighting for liver fat quantification in patients with...
متن کاملAn optimized fast protocol for magnetic resonance imaging of the temporomandibular joint.
OBJECTIVES To provide a fast protocol for MR imaging of the TMJ with high contrast resolution of both soft tissue and joint fluid. METHODS A fast turbo-spin echo (TSE) pulse sequence was developed. The new technique was compared with T1W conventional spin echo (CSE) and T2W TSE sequences in imaging 57 TMJs in 50 patients. Disc location and contour and bone delineation were assessed on three i...
متن کاملTemporomandibular joint inflammation: comparison of MR fast scanning with T1- and T2-weighted imaging techniques.
One hundred painful temporomandibular joints in 100 patients were studied with high-field, surface-coil MR imaging. Partial flip angle or GRASS (gradient-recalled acquisition in steady state) and either T1-weighted or spin-echo long TR/short-long TE imaging techniques were used to assess the relative sensitivity and accuracy of these techniques in detecting joint fluid. Intraarticular fluid, in...
متن کاملI-51: Pioneering New Approaches to Reproductive Imaging
Background: Gynecologic conditions including uterine fibroids, adenomyosis and endometriosis lead to significant impairment in women’s’ lives and significant expen- Abstracts of the 12th Royan International Congress on Reproductive Biomedicine International Journal of Fertility & Sterility (IJFS), Vol 5, Suppl 1, Summer 2011 24 ditures of health care dollars. However, many women have symptoms l...
متن کاملDynamic MRI of the temporomandibular joint at 3 Tesla using a gradient echo sequence
Introduction Temporomandibular joint (TMJ) dysfunction is a cause of headache, facial pain and referred otalgia, which can be quite debilitating to patients. MRI has been applied in limited circumstances to define contours of the articular disc, and to evaluate disc motion during translation of the condyle with opening and closing of the mouth. Broad implementation of an effective protocol has ...