Superconducting Transition Edge Sensor for Gamma-Ray Spectroscopy

نویسندگان

  • Masashi Ohno
  • Tomoya Irimatsugawa
  • Hiroyuki Takahashi
  • Chiko Otani
  • Takashi Yasumune
  • Koji Takasaki
  • Chikara Ito
  • Takashi Ohnishi
  • Shinichi Koyama
  • Shuichi Hatakeyama
  • R. M. Thushara Damayanthi
چکیده

Superconducting Transition edge sensor (TES) coupled with a heavy metal absorber is a promising microcalorimeter for Gammaray (γ-ray) spectroscopy with ultra-high energy resolution and high detection efficiency. It is very useful for the non-destructed inspection of the nuclide materials. High resolving power of γ-ray peaks can precisely identify multiple nuclides such as Plutonium (Pu) and Actinides with high efficiency and safety. For this purpose, we have developed the TES coupled with a tin absorber. We suggest the new device structure using the gold bump post which connects a tin absorber to the thermometer of the superconducting Ir/Au bilayer. High thermal conductivity of the gold bump post realized strong thermal coupling between the thermometer and the γ-ray absorber, and it brought the benefit of large pulse height and fast decay time. Our TES achieved the good energy resolution of 84 eV FWHM at 59.5 keV. Using this TES device, we also succeeded to demonstrate the nuclear material measurements. In the measurement of a Pu sample, we detected the sharp γ-ray peaks from 239Pu and 240Pu, and of a Fission Products (FP) sample, we observed fluorescence X-ray peaks emitted by the elements contained in FP. The TES could resolve the fine structures of each fluorescence X-ray line like Kα1 and Kα2. In addition to that, we developed the TES coupled with tantalum absorber, which is expected to have higher absorption efficiency for γ-rays. This device reported the best energy resolution of 465 eV at 662 keV. key words: transition edge sensor, gamma-ray, nuclide analysis

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transition from analogue-to-digital nuclear electronics for precise gamma radiation spectroscopy: advantages and limitations

In this paper, digital signal processing for precise gamma ray spectroscopy is presented. The basis of this system is a 14bit waveform digitizer which samples the output of pre-amplifier signals directly. The advantages and limitations of the digital spectrometer compared with analog spectrometer has been tested and analyzed from precise gamma ray spectroscopy point of view. The results shows t...

متن کامل

Cryogenic Detector Development at LLNL: Ultraviolet, X-ray, Gamma-ray and Biomolecule Spectroscopy

We are developing low-temperature detectors for optical, ultraviolet, X-ray, and gamma-ray spectroscopy, and for biomolecular mass spectrometry. We present here a survey of our recent work in developing these detectors and some of the first results in applying these detectors for materials analysis and biomolecular mass spectrometry. We have measured thin-film Nb/Al/Al2O3/Al/Nb superconducting ...

متن کامل

Response of a Superconducting Transition-Edge Sensor Microcalorimeter with a Mushroom-shaped Absorber to L X-rays Emitted by Transuranium Elements

A four-pixel-array superconducting transition-edge sensor (TES) microcalorimeter with a mushroom-shaped absorber was fabricated for the energy dispersive spectroscopy performed on a transmission electron microscope. The TES consists of a bilayer of Au/Ti with either a 50nm or 120-nm thickness. The absorber of 5.0 μm thick is made from a Au layer and its stem is deposited in the center of the TE...

متن کامل

Soft X-ray absorption spectroscopy and resonant inelastic X-ray scattering spectroscopy below 100 eV: probing first-row transition-metal M-edges in chemical complexes.

X-ray absorption and scattering spectroscopies involving the 3d transition-metal K- and L-edges have a long history in studying inorganic and bioinorganic molecules. However, there have been very few studies using the M-edges, which are below 100 eV. Synchrotron-based X-ray sources can have higher energy resolution at M-edges. M-edge X-ray absorption spectroscopy (XAS) and resonant inelastic X-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • IEICE Transactions

دوره 100-C  شماره 

صفحات  -

تاریخ انتشار 2017