Multicenter, randomized, tandem evaluation of EndoRings colonoscopy--results of the CLEVER study.

نویسندگان

  • Vincent K Dik
  • Ian M Gralnek
  • Ori Segol
  • Alain Suissa
  • Tim D G Belderbos
  • Leon M G Moons
  • Meytal Segev
  • Sveta Domanov
  • Douglas K Rex
  • Peter D Siersema
چکیده

BACKGROUND AND STUDY AIMS Adenoma miss rate during colonoscopy has become a widely acknowledged proxy measure for post-colonoscopy colorectal cancer. Among other reasons, this can happen because of inadequate visualization of the proximal aspects of colonic folds and flexures. EndoRings (EndoAid Ltd., Caesarea, Israel) is a silicone-rubber device that is fitted onto the distal end of the colonoscope. Its flexible circular rings engage and mechanically stretch colonic folds during withdrawal. The primary aim of this study was to compare adenoma miss rates between standard colonoscopy and colonoscopy using EndoRings. METHODS In this multicenter, randomized, tandem colonoscopy study, we performed same-day, back-to-back colonoscopies with EndoRings followed by standard colonoscopy, or vice versa. RESULTS After exclusion of 10 patients for protocol violations, 116 patients (38.8% female; mean age 58.7) remained for analysis. The adenoma miss rate of EndoRings colonoscopy (7/67; 10.4%) was significantly lower (P<0.001) compared with standard colonoscopy (28/58; 48.3%). Similar results were found for polyp miss rates: EndoRings (9.1%) and standard colonoscopy (52.8%; P<0.001). Mean cecal intubation times (9.3 vs. 8.4 minutes; P=0.142) and withdrawal times (7.4 vs. 7.2 minutes; P=0.286), respectively, were not significantly different between EndoRings and standard colonoscopy. Mean total procedure time was longer with EndoRings than with standard colonoscopy (21.6 vs. 18.5 minutes, P=0.001) as more polyps were removed. CONCLUSIONS This study demonstrates that colonoscopy with EndoRings has lower adenoma and polyp miss rates than standard colonoscopy, which may improve the efficacy particularly of screening and surveillance colonoscopies. ClinicalTrials.gov NCT01955122.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Quick and Sensitive Liquid Chromatography-Tandem Mass Spectrometry (LC-MS) Method for the Evaluation of Two Formulations of Amlodipine and Atorvastatin in Healthy Male Volunteers

An open-label, single-dose, randomized, 2-way crossover study was conducted in fasted healthy Iranian male volunteers. Eligible participants randomly assigned in a 1:1 ratio to be given one tablet of the test or reference formulation, followed by a 2-week washout period and administration of the exchange formulation. A quick and susceptible Liquid Chromatography–tandem Mass Spectro...

متن کامل

Comparing Vitamin B12 and Nitrous Oxide Neurotoxicity in Operating Room Staff and other Hospital Staff: A Multicenter Study

Background and purpose: Nitrous oxide (N2O) is an anesthetic widely used in operating rooms. Chronic exposure to N2O causes decrease in mental performance, peripheral neuropathy, and polyneuropathy. The aim of this study was to compare neurological complications caused by N2O exposure between operating room staff and other hospital staff. Materials and methods: In this multicenter cohort study...

متن کامل

مقایسه اثرات آرام‌بخشی پروپوفول- فنتانیل با میدازولام– مپریدین در بیماران تحت کولونوسکوپی انتخابی

Background and purpose: Colonoscopy is an invasive short-lasting procedure causes the patient's considerable pain, discomfort and anxiety. Therefore, various types of sedation and analgesia techniques have been used during the procedure. The aim of this study was to compare the quality of sedation/analgesia of propofol-fentanyl and midazolam-meperidine combinations in patients undergoing electi...

متن کامل

Effectiveness of Diclofenac Sodium Suppository in Reduction of Pain and Dosage of Fentanyl in Patients Undergoing Colonoscopy: A Randomized Clinical Trial

Background and purpose: Opioid analgesics cause bradycardia and respiratory depression.  The aim of this study was to investigate the efficacy of diclofenac suppository on pain and dose reduction of injectable fentanyl in patients undergoing colonoscopy. Materials and methods: In a clinical trial, 500 patients undergoing colonoscopy were randomly divided into two groups to receive either diclo...

متن کامل

Sedation with etomidate-fentanyl versus propofol-fentanyl in colonoscopies: A prospective randomized study

Abstract Background: The combination of propofol-fentanyl for sedation during colonoscopy is characterized by the frequent incidence of side effects. Etomidate-fentanyl provides fewer hemodynamic and respiratory complications. The aim of our study was to compare the safety and efficacy of propofol-fentanyl and etomidate-fentanyl for conscious sedation in elective colonoscopy. Methods: This do...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Endoscopy

دوره 47 12  شماره 

صفحات  -

تاریخ انتشار 2015