Detection of Several Flicker Sources in a Non-radial Power System
نویسندگان
چکیده
Detection of flicker sources is the first step to mitigate the effect of flicker in power system. In this paper, in order to reduce the number of measurement devices, instantaneous voltages are estimated by using state estimation methods and then root mean square of the voltages and currents variation are detected and then sign of flicker powers is obtained in selected branches. By comparing the sign of flicker power with direction of fundamental active power, the places of flicker sources are obtained. For validation, the 6bus non-radial network is simulated and algorithm for flicker sources detection is tested in this paper. The simulations results show that by using the proposed algorithm, all flicker sources in a non-radial network can be detected correctly.
منابع مشابه
Radial Basis Neural Network Based Islanding Detection in Distributed Generation
This article presents a Radial Basis Neural Network (RBNN) based islanding detection technique. Islanding detection and prevention is a mandatory requirement for grid-connected distributed generation (DG) systems. Several methods based on passive and active detection scheme have been proposed. While passive schemes have a large non detection zone (NDZ), concern has been raised on active method ...
متن کاملImproving the Method of Location Identification and Determining the Effect of Each Flicker Source in Distribution Networks
Voltage flicker phenomenon is one of the main power quality problems in today's power networks. Before any compensation operation for this phenomenon, the location of each flicker sources must be identified and the effect of each of them on the network flicker value must be determined. Also, methods that require least number of monitoring points are more in demand due to the limitations of meas...
متن کاملA Comparison between SVC and STATCOM in Flicker Mitigation of Electric Arc Furnace using Practical Recorded Data
Electric arc furnace (EAF) is one of the largest loads in electric power systems. It is highly time varying and nonlinear. Its reactive power variations cause voltage fluctuations in nearby system which is known as flicker. On the other hand the nonlinear voltage-current characteristic causes strong voltage and current harmonics in EAF. To this end Flexible AC Transmission Systems (FACTS) techn...
متن کاملComparison of Binomial and Power Equations in Radial Non-Darcy Flows in Coarse Porous Media
Analysis of non-laminar flows in coarse alluvial beds has a wide range of applications in various civil engineering, oil and gas, and geology problems. Darcy equation is not valid to analyze transient and turbulent flows, so non-linear equations should be applied. Non-linear equations are classified into power and binomial equations. Binomial equation is more accurate in a wide range of velocit...
متن کاملDetermining the Optimal Location and Amount of Distributed Generation Sources in an Unbalanced Radial Distribution Grid
Optimal placement of scattered generator sources in the main and secondary feeders of radial grid reduces energy losses, releases the capacity of existing feeders and improves the existing voltage profile. In this project determine the location and suitable for the production of production resources S cattered in radial feeders of unbalanced distribution networks, a new formulation solution is ...
متن کامل