An approximate two-dimensional transient analysis of charge transport in a buried-channel charge-coupled device
نویسندگان
چکیده
2014 A method for the approximate transient analysis of the BCCD is presented. The solution is obtained by considering only the nearly-linear Poisson/Laplace’s equation in a completelydepleted/charge-neutral region and subsequent estimate of carrier flow across the interface between the charged and neutral regions. Additional factors are introduced in the solution of the equations to ensure that current continuity and charge conservation are maintained. Hence mechanisms leading to small transfer inefficiencies cannot be represented. An example is presented showing the effect of clock waveform overlap on the transfer process. In addition quasi static potential and charge distributions are compared with a one-dimensional steady state exact simulation.
منابع مشابه
Transient Two-Dimensional (r-z) Cyclic Charging/Discharging Analysis of Space Thermal Energy Storage Systems (RESEARCH NOTE)
A two-dimensional transient axi-symmetric model was developed to study the effects of various thermal and geometric parameters on cyclic heating and cooling modes of a phase-change thermal energy storage system. The high-temperature thermal energy storage device utilizes LiH for heat sink applications to store the waste heat generated during power-burst periods. The stored heat is then discharg...
متن کاملTwo-Dimensional Flow Analysis of Nanofluid through a Porous Channel with Suction/Injection at Slowly Expanding/Contracting Walls using Variation of Parameter Method
In this work, variation of parameter method is applied to study two-dimensional flow of nanofluid in a porous channel through slowly deforming walls with suction or injection. The results of the developed approximate analytical solution using the variation of parameter method is verified with the results of numerical solution using fourth-order Runge-Kutta method coupled with shooing techniques...
متن کاملمقایسه سنسورهای دیجیتالی Charge-Coupled Device با Photostimulable Phosphor Storage Plate در تشخیص شکستگی عمودی ریشه در دندانهای اندو شده (مطالعه آزمایشگاهی)
Objective: Vertical root fracture (VRF) is among the most common causes of endodontic treatment failures. This study aims to compare charge-coupled devices (CCD) and photostimulable phosphor plates (PSP) for detection of vertical root fractures in endodontically treated teeth. Methods: In this diagnostic in vitro study, 40 maxillary anterior teeth were selected and after preparation and roo...
متن کاملThe overlaid CCD : a bulk-integrated double-channel charge-coupled device
2014 A novel charge-coupled device structure operating by transferring charge packets on two distinct levels which are overlaid in the semiconductor bulk is described and analysed. This bulk-integrated device is twice as compact and has a reduced driving power consumption per bit, compared to conventional buried-channel CCD’s, still enjoying bulk-channel operation. Furthermore, the overlaid CCD...
متن کاملUse of a Two-Channel Moiré Wavefront Sensor for Measuring Topological Charge Sign of the Vortex Beam and Investigation of Its Change Due to an Odd Number of Reflections
One of the solutions of the Helmholtz equation is the vortex beams. In the recent decades, production and applications of these types of beams have found serious attentions. Determination of the vortex beam topological charge and its sign are very important issues. Odd number of reflections of the vortex beam changes its vorticity. In this paper, we have used a q-plate to generate a vortex beam...
متن کامل