Delayed onset porous polyethylene implant-related inflammation after orbital blowout fracture repair: four case reports
نویسندگان
چکیده
BACKGROUND Porous polyethylene implants are commonly used in orbital blowout fracture repair because of purported biocompatibility, durability, and low frequency of complications. Delayed inflammation related to porous polyethylene sheet implants is very rare and no case series of this condition have been reported. CASE PRESENTATION This is a retrospective review of clinical presentations, radiographic findings, histopathological findings, treatments, and outcomes of patients who developed delayed complications in orbital blowout fracture repair using porous polyethylene sheets. Four male patients were included with a mean age of 49 years (range 35-69 years). Blowout fracture repair was complicated with implant-related inflammation 10 months, 2 years, 3 years, and 8 years after surgery. Chronic and subacute orbital inflammatory signs were noted in two patients and acute fulminant orbital inflammation was found in two patients. Three patients developed peri-implant abscesses and one patient had a soft tissue mass around the implant. All patients underwent implant removal and two of these patients with paranasal sinusitis had sinus surgery. Histopathological findings revealed chronic inflammatory changes with fibrosis, and one patient had foreign body granuloma with culture positive Staphylococcus aureus. CONCLUSIONS Delayed complications with porous polyethylene sheets used in orbital blowout fracture repair may occur many years following the initial surgery in immunocompetent patients. Low-grade or fulminant inflammation could complicate blowout fracture repair related with the implant.
منابع مشابه
Delayed Orbital Hemorrhage around Alloplastic Implants after Blowout Fracture Reduction
Alloplastic implants have been used to repair orbital wall fractures in most cases. Orbital hemorrhage is a rare complication of these implants and has been reported rarely in Korea. The purpose of this article is to report a late complication case focusing on their etiology and management. A 20-year-old male patient underwent open reduction with Medpor (porous polyethylene) insertion for bilat...
متن کاملOrbital cellulitis: a rare complication after orbital blowout fracture.
PURPOSE To report the incidence of orbital cellulitis after orbital blowout fracture. DESIGN Retrospective, noncomparative, interventional case series. PARTICIPANTS All patients with orbital cellulitis and a history of recent orbital fracture. METHODS A medical record review of clinical history, imaging studies, and surgical and treatment outcome was performed. MAIN OUTCOME MEASURES Res...
متن کاملRetrobulbar Hematoma Following Orbital Floor Reconstruction
DESCRIPTION Ten days after reconstruction of an orbital floor blow out fracture with a porous polyethylene implant, a 23-year-old man presented with sudden onset of swelling and proptosis of the right eye following weightlifting.
متن کاملThe Merits of Mannitol in the Repair of Orbital Blowout Fracture
BACKGROUND One of the main concerns in orbital blowout fracture repair is a narrow operation field, due mainly to the innate complex three dimensions of the orbit; however, a deep location and extensive area of the fracture and soft tissue edema can also cause concern. Swelling of the orbital contents progresses as the operation continues. Mannitol has been used empirically in glaucoma, cerebra...
متن کاملA Case of Orbital Abscess following Porous Orbital Implant Infection
PURPOSE We present a case of orbital abscess following porous orbital implant infection in a 73-year-old woman with rheumatoid arthritis. METHODS Just one month after a seemingly uncomplicated enucleation and porous polyethylene (Medpor) orbital implant surgery, implant exposure developed with profuse pus discharge. The patient was unresponsive to implant removal and MRI confirmed the presenc...
متن کامل