Application of 2-octyl-cyanoacrylate for corneal perforation and glaucoma filtering bleb leak

نویسندگان

  • Motonori Okabe
  • Kiyotaka Kitagawa
  • Toshiko Yoshida
  • Chika Koike
  • Takeshi Katsumoto
  • Etsuko Fujihara
  • Toshio Nikaido
چکیده

BACKGROUND This paper reports on the efficacy of a tissue adhesive, 2-octyl-cyanoacrylate, in the treatment of corneal perforation and glaucoma filtering bleb leak. METHODS Two eyes from two patients with corneal perforation or laceration and two eyes from two patients with bleb leak were included. The patients underwent application of 2-octyl-cyanoacrylate onto the perforated or leaking site, and a hydrogel contact lens was applied as a bandage. We also evaluated the in vitro cell toxicity of 2-octyl-cyanoacrylate in HeLa cells. RESULTS The two cases of corneal perforation were repaired within 22 days with one application of the tissue adhesive. The two cases of bleb leak were repaired with 2-4 applications of the tissue adhesive over 134 (range 17-134) days). There were no recurrences or adverse effects during a mean follow-up period of 12.7 months. In vitro testing revealed that 2-octyl-cyanoacrylate was markedly toxic to HeLa cells. CONCLUSION Four patients with corneal perforation or bleb leak were successfully managed using 2-octyl-cyanoacrylate tissue adhesive. This simple and easy surgical technique may become an alternative therapeutic option for corneal perforation or bleb leak, although several applications of this tissue adhesive may be required. Although 2-octyl-cyanoacrylate was toxic to HeLa cells, no adverse clinical effects were noted using this adhesive.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Closure of leaking filtering blebs with cyanoacrylate tissue adhesive.

Five leaking filtering blebs, occurring between 10 months and 21 years after trabeculectomy, were closed with cyanoacrylate tissue adhesive. Filtering bleb integrity was preserved in four cases, so that additional microsurgery was avoided. The only problem associated with use of tissue adhesive was the development of corneal abrasions in three cases. Although it is an accepted treatment for the...

متن کامل

Conjunctival advancement for late-onset filtering bleb leaks: indications and outcomes.

OBJECTIVE To determine the indications and outcome of conjunctival advancement surgery for late-onset filtering bleb leaks. PATIENTS AND METHODS Retrospective medical record review of a consecutive case series of all patients who underwent conjunctival advancement surgery for persistent late-onset glaucoma filtering bleb leaks at a tertiary referral center between December 1, 1985, and April ...

متن کامل

The Efficacy of N-Butyl-2 Cyanoacrylate (Histoacryl) for Sealing Corneal Perforation: A Clinical Case Series and Review of the Literature

Purpose: To investigate the efficacy of corneal gluing procedures for corneal perforations of mixed aetiologies in a tertiary eye hospital in Sydney, Australia. Design: Retrospective case series. Methods: Episodes of corneal gluing procedures were identified from the Sydney Eye Hospital surgical database over 42 months from January 2010. All gluing procedures in this study were conducted in the...

متن کامل

Comparison of Tensile Strength of Fibrin Glue, 2-Octyl Cyanoacrylate, Liquid Ocular Bandage, and Conventional Nylon 10-0 Sutures in Corneal Laceration Repair in an Animal Model

Objective: To compare the tensile strength of fibrin glue, 2-octyl cyanoacrylate, and liquid ocular bandage to conventional nylon 10-0 sutures in sealing central linear corneal lacerations. Methods: An experimental in-vitro study was performed on 74 porcine eyes. A 27-gauge needle connected to an infusion system with balanced salt solution was inserted into the anterior chamber and the bottle h...

متن کامل

Pathological Evaluation of Two Techniques of Amniotic Membrane Patching on Experimentally Induced Corneal Lesions in Dogs

Objective- This study was performed to evaluate and compare grossly and pathologically two surgical techniques of amniotic membrane patching on experimental corneal alkali burn in dogs.   Design- Experimental study.   Animals- Fifteen healthy dogs   Procedures- The central corneas of the dogs were inflicted by applying a round filter paper, 6.0 mm in diameter, soaked in 1 N NaOH for 60 sec. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2013